Keysight (Agilent) 83483A REPAIR and Keysight (Agilent) 83483A CALIBRATION

The Keysight (Agilent) 83483A is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 83483A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 83483A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   Keysight (Agilent) 83483A   Description / Specification:    
Keysight (Agilent) 83483A Dual Channel 20 GHz Electrical Plug-In Module

The Agilent 83483A is a dual electrical channel module plug-in for 83480A and 86100A digital communications analyzer. Has two 20 GHz bandwidth electrical channels with user selectable 12.4 or 20 GHz bandwidths. The lower bandwidth mode provides excellent oscilloscope noise performance for accurate measurement of small signals. The high bandwidth mode provides high-fidelity display and measurement of very high-speed waveforms. 2.5 GHz bandwidth trigger channel. Specifications. Bandwidth: (-3 dB) dc to 12.4 or 20 GHz, user selectable. DC Accuracy - single marker 12.4 GHz bandwidth: ± 0.4% of full scale, ± 2 mV ± 1.5% (reading - channel offset). DC Accuracy - single marker 20 GHz bandwidth: ± 0.4% of full scale, ± 2 mV ± 3% (reading - channel offset). DC Difference - two marker accuracy on same channel 12.4 GHz: ±0.8% of full scale, ±1.5% of delta marker reading. DC Difference - two marker accuracy on same channel 20 GHz: ±0.8% of full scale, ±3% of delta marker reading. Transition Time (10% - 90%) characteristic, calculated from T=0.35/BW, electrical: 28.2 ps (12.4 GHz bandwidth), 17.5 ps (20 GHz bandwidth). RMS Noise Typical: 0.25 mV (12.4 GHz bandwidth), 0.5 mV (20 GHz bandwidth). Scale Factor (full scale is eight divisions): 1 mV/div (minimum), 100 mV/div (maximum). DC Offset Range: ±500 mV. Nominal Input Impedance: 50 ohm. Connectors: 3.5mm (m), channel and trigger. Input Re ection/Return Loss: <=5% for 30 ps rise time. Number of Channels: 2. Dynamic Range/Maximum Specified Input Power: ±400 mV relative to channel offset. Maximum Safe Input: ±2V + peak ac (+16 dBm).



 

Standard Calibration $475.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 83483A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your Keysight (Agilent) 83483A REPAIR and/or Keysight (Agilent) 83483A Dual Channel 20 GHz Electrical Plug-In Module CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: