Keysight (Agilent) 83623A REPAIR and Keysight (Agilent) 83623A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 83623A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 83623A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   Keysight (Agilent) 83623A   Description / Specification:    
Keysight (Agilent) 83623A 20 GHz Synthesized Sweeper

The HP 83623A synthesized sweeper is the standard of excellence for applications requiring the high performance and accuracy of a synthesized source and the speed and versatility of a sweep oscillator. Synthesized broadband frequency coverage and precise 1 Hz frequency resolution (Option 008) are generated by indirect synthesis, enabling the HP 83623A to achieve low single-sideband phase noise performance. The HP 83623A delivers excellent harmonic performance with harmonics at least 50 dB below the carrier from 2.2 to 20 GHz. High-performance pulse modulators with >80 dB on/off ratio and rise/fall times < 10 ns (Option 006), make the HP 83623A suitable for the most demanding pulse modulation applications. In addition to its linear AM mode (100%/V), the HP 83623A offers a scan modulation mode (10 dB/V). Both modes have dc-coupled amplitude modulation capability with a 3 dB bandwidth of 100 kHz. and 99.7% (50 dB) of modulation depth, Pulse and amplitude modulation capabilities can be used independently and simultaneously. The HP 83623A also offers dc-coupled frequency modulation capabilities with rates up to 8 MHz. Specifications. Frequency Range: 10 MHz to 20 GHz. Resolution: 1 kHz standard, 1 Hz optional. RF Output Range: +20 to -110 dBm with Opt 001. Resolution: 0.02 dB. Maximum Leveled Power: + 17 dBm. Pulse modulation On/off ratio: > 80 dB. Rise and fall times: <25 ns (< 10 ns optional). Minimum internally leveled RF pulse width: < 1us. Minimum RF pulse width: <50 ns (15 ns with Opt 006). Scan and amplitude modulation Rates (3dB BW): dc to 100 kHz. Depth: 0 to 90% (20 dB) aIld 0 to 99.7% (50 dB) above 10 Hz. Sensitivity: 100%/V and 10 dB/V. Frequency modulation Locked mode Modulation rate (3 dB BW, 500 kHz deviation): 100 kHz to 8 MHz. Maximum deviations: 8 MHz. Options. Opt 001: Add Step Attenuator. Opt 002: Internal Modulation Generator. Opt 003: Delete Front Panel Keyboard/Display. Opt 004: Rear Panel RF Output. Opt 006: Fast Pulse Modulation. Opt 008:1 Hz Frequency Resolution. Opt 700: Mate System Compatibility.



 

Standard Calibration $665.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 83623A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your Keysight (Agilent) 83623A REPAIR and/or Keysight (Agilent) 83623A 20 GHz Synthesized Sweeper CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: