Keysight (Agilent) 86107A REPAIR and Keysight (Agilent) 86107A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 86107A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 86107A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   Keysight (Agilent) 86107A   Description / Specification:    
Keysight (Agilent) 86107A Precision Timebase Reference Plug-in Module

The Agilent 86107A is a precision timebase reference plug-in module for 86100 Infiniium DCA. Jitter performance has been reduced by almost an order of magnitude to 200 fs RMS. Oscilloscope jitter is virtually eliminated! The reduced jitter of the 86107A precision timebase module allows you to measure the true jitter of your signal. The 86107A requires a 10, 20 or 40 GHz electrical reference clock that is synchronous with the signal under test. Timebase resolution has also been improved from 10 ps/division to 2 fs/division, a 5 times improvement. Trigger Bandwidth: Option 010, 2.4 to 4.0 GHz and 9.0 to 12.6 GHz; Option 020, 9.0 to 12.6 GHz and 18.0 to 25.0 GHz; Option 040, 9.0 to 12.6 GHz, 18.0 to 25.0 GHz and 39.0 to 43.0 GHz. Typical Jitter (RMS): Option 010, <280 fs (2.4 to 4.0 GHz trigger) and <200 fs (9.0 to 12.6 GHz trigger); Option 020, <280 fs; Option 040, <250 fs (9.0 to 12.6 GHz, 18.0 to 25.0 GHz trigger bands) and <200 fs (38 to 45 GHz trigger). Time Base Linearity Error: < 100 fs. Input Signal Type: Synchronous clock, no constraint on waveform shape. Input Signal Level: 0.5 - 1.0 Vpp, 0.2 - 1.5 Vpp (Typical functional performance). DC Offset Range: ±200 mV. Required Trigger Signal-to-Noise Ratio: >= 200 : 1.



 

Standard Calibration $1,115.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 86107A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your Keysight (Agilent) 86107A REPAIR and/or Keysight (Agilent) 86107A Precision Timebase Reference Plug-in Module CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: