Keysight (Agilent) 86140A REPAIR and Keysight (Agilent) 86140A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 86140A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 86140A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Optical Spectrum Analyzer, OSA?
Shop for Comparable Products on our
 used Optical Spectrum Analyzer, OSA page or new Optical Spectrum Analyzer, OSA page

As an alternative New Ridge Technologies offers the NRT-8000, the world’s Smallest Optical Spectrum Analyzer with built in “live wavelength calibration” for C-Band applications.  More
   Keysight (Agilent) 86140A   Description / Specification:    
Keysight (Agilent) 86140A 600 to 1700nm Standard Performance Optical Spectrum Analyzer

600 nm to 1700 nm, Standard performance benchtop Optical Spectrum Analyzer, 9/125 um optical input. Wavelength Reproducibility (1 min): ±0.003 nm. Wavelength Span Range: 0.2 nm to full range and zero span. Wavelength Absolute Accuracy: ±0.5 nm. Wavelength Span Linearity: 1525 nm - 1570 nm, ±0.02 nm. Wavelength Span Linearity: ±0.05 nm, for spans <40nm. Maximum Sensitivity (1250-1610 nm): –90 dBm. Maximum Sweep Rate: 40 nm/50 ms. Max Measurement Power: +15 dBm per channel (+12 dBm per channel, 1000–1525 nm), +30 dBm total. Dynamic Range In 0.1 nm resolution 1250–1610 nm (chop mode on) ±0.5 nm, ±1 nm, ±5 nm: 70 dB. Resolution Bandwidth: 0.07 nm, 0.1 nm, 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm, 10 nm



Looking for a replacement? Try the  DEVISER AE8600

Standard Calibration $540.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 86140A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Coherence Length
Average distance over which superimposed waves lose their phase relationships

Linewidth
Linewidth is the width of a spectral line in terms of wavelength, wave number and frequency.

Power Flatness Versus Wavelength
When changing the wavelength at constant power setting and recording the differences between actual and displayed power levels, the power flatness is ± half the span (in dB) between the maximum and the minimum of the measured power levels.

Spectral Width
Spectral Width is the wavelength interval over which the magnitude of all spectral components is equal to or greater than a specified fraction of the magnitude of the component having the maximum value. In optical communications applications, the usual method of specifying spectral width is the full width at half maximum. This is the same convention used in bandwidth, defined as the frequency range where power drops by less than half (at most -3 dB).

Telecom Bands
Optical fiber communications typically operate in a wavelength region corresponding to one of the following Bands. O Band (original): 1260–1360 nm. E Band (extended): 1360–1460 nm. S Band (short wavelengths): 1460–1530 nm. C Band (conventional): 1530–1565 nm. L Band (long wavelengths): 1565–1625 nm. U Band (ultralong wavelengths): 1625–1675 nm


Please contact us for your Keysight (Agilent) 86140A REPAIR and/or Keysight (Agilent) 86140A 600 to 1700nm Standard Performance Optical Spectrum Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*