Keysight (Agilent) 86141B REPAIR and Keysight (Agilent) 86141B CALIBRATION

The Keysight (Agilent) 86141B is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 86141B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 86141B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Optical Spectrum Analyzer, OSA?
Shop for Comparable Products on our
 used Optical Spectrum Analyzer, OSA page or new Optical Spectrum Analyzer, OSA page

As an alternative New Ridge Technologies offers the NRT-8000, the world’s Smallest Optical Spectrum Analyzer with built in “live wavelength calibration” for C-Band applications.  More
   Keysight (Agilent) 86141B   Description / Specification:   Spec Sheet 
Keysight (Agilent) 86141B 600 to 1700nm Flexible Performance Optical Spectrum Analyzer

The Agilent 86141B is a grating-based Flexible performance Optical Spectrum Analyzer that displays the amplitude of light versus wavelength over a 600 to 1700 nm wavelength range. The OSA uses a patented double-pass monochromator design to simultaneously achieve high sensitivity and dynamic range with a fast sweep time. This is key for characterizing DWDM components and multiple channel systems, especially in a manufacturing environment where speed, accuracy, and throughput are critical. A VGA port allows a PC monitor to be connected directly to the OSA screen, and a parallel (Centronics) interface enables clear color copies of measurement results to be generated. The GPIB interface provides high transfer speeds across the bus which are critical in a high throughput environment. The uncluttered front panel has been designed to compliment the intuitive graphical user interface (GUI) that has been significantly enhanced over the previous generation. Specifications. 50 um optical input, with Filter Mode. Wavelength Range: 600 nm to 1700 nm. Wavelength Reproducibility <= 1 min: ±0.002 nm. Wavelength Span Range: 0.2 nm to full range and zero span. Wavelength Absolute Accuracy: ±0.5 nm. Wavelength Span Linearity: 1525 nm - 1570 nm, ±0.01 nm. Wavelength Span Linearity: for spans <40 nm, ±0.02 nm. Maximum Sensitivity (1250-1610 nm): –90 dBm. Maximum Sweep Rate: 40 nm/56.3 ms. Max Measurement Power: +15 dBm per channel, +30 dBm total. Dynamic Range: 70 dB. Resolution Bandwidth: 0.07 nm, 0.1 nm, 0.2 nm, 0.3 nm, 0.5 nm, 1 nm, 2 nm, 5 nm, 10 nm. Options. Option 001: Current Source. Option 002: White Light Source. Option 004: 1300 nm/ 1550 nm EELED. Option 005: 1550 nm EELED. Option 006: Wavelength Calibrator.



Looking for a replacement? Try the  DEVISER AE8600

Standard Calibration $540.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 86141B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
Optical power referenced to 1 millimatt

Multimode Fiber
Multimode Fiber has a large core (almost always 62.5 microns - a micron is one one millionth of a meter - but sometimes 50 microns) and is used with LED sources at wavelengths of 850 and 1300 nm for short distance, lower speed networks like LANs. Both multimode and singlemode fiber have an outside diameter of 125 microns - about 5 thousandths of an inch - just slightly larger than a human hair.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Refractive Index
The refractive index or index of refraction of a substance is a measure of the speed of light in that substance. It is expressed as a ratio of the speed of light in vacuum relative to that in the considered medium. The velocity at which light travels in vacuum is a physical constant, and the fastest speed at which energy or information can be transferred. However, light travels slower through any given material, or medium, that is not vacuum.

Total insertion loss
A measure of the loss of light within an optical component


Please contact us for your Keysight (Agilent) 86141B REPAIR and/or Keysight (Agilent) 86141B 600 to 1700nm Flexible Performance Optical Spectrum Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.