Keysight (Agilent) E3630A REPAIR and Keysight (Agilent) E3630A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) E3630A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E3630A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   Keysight (Agilent) E3630A   Description / Specification:    
Keysight (Agilent) E3630A Triple Output DC Power Supply

The Agilent E3630A Triple Output DC Power Supply has 0.01% load and line regulation which keeps the outputs steady with changes of the power line and load. The low normal-mode noise specification of 350 µV rms assures clean power for precision circuitry, and the low common-mode current specification of 1 µA rms minimizes line frequency current injection. It has separate digital panel meters to monitor both the voltage and current of any output simultaneously. An LED indicator for each output lets the user know when any supply is overloaded. All the outputs are protected against overload and short-circuit damage. Protection circuits prevent output voltage overshoot when supply is turned on and off. The +6 V output of E3630A employs current foldback; all others are current limited. The three outputs include, one 0 to 6 V output to power logic or other circuitry and one 0 to +20 V and 0 to -20 V to power linear circuits. The 0 to +20 V and 0 to -20 V outputs track to within 1%. The 0 to -20 V output can be set to any value less than the 0 to +20 V output. One voltage control may be used to vary both simultaneously. Specifications. Number of output ranges: 1. Output ratings: Output 1; 0 to 6 V, 0 to 2.5 A. Output 2; 0 to +20 V, 0 to 0.5 A. Output 3; 0 to -20 V, 0 to 0.5 A. Power (max.): 35W. Load and line regulation: 0.01% +2 mV. Ripple and noise: rms 350 µV, peak-to-peak 1.5 mV. Control mode: CV/CL (±20 V), CV/CF (+6 V). Resolution: Voltage 10 mV, Current 10 mA.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E3630A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your Keysight (Agilent) E3630A REPAIR and/or Keysight (Agilent) E3630A Triple Output DC Power Supply CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: