Custom-Cal has a high success rate in the repair of the ANRITSU MP1763B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU MP1763B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Pattern Generator?
Shop for Comparable Products on our
 used Pattern Generator page

 
   ANRITSU MP1763B   Description / Specification:    
ANRITSU MP1763B Pulse Pattern Generator

0.05 to 12.5 GHz Pulse Pattern Generator. External clock; Input level: 0.4 to 2.5 Vp-p. Input waveform: Square wave with rise/fall time of less than 1 ns, duty factor 50% (0.05 to 0.5 GHz); Sinusoidal wave or square wave with rise/fall time of less than 1 ns, duty factor 50% (>0.5 GHz). Input connector: APC-3.5. Internal clock; Frequency setting resolution: 1 kHz, 1 MHz. Stability: ±1 ppm. SSB phase noise (at 10kHz offset, 1 Hz bandwidth): -85 dBc/Hz (0.05 to 4 GHz), -80 dBc/Hz (4 to 8 GHz), -75 dBc/Hz (8 to 10 GHz), - 70 dBc/Hz (10 to 12.5 GHz). Reference signal: 10 MHz (internal/external, selectable). Pattern; Pseudorandom binary sequence pattern (PRBS): Pattern: 2^n-1 (n: 7, 9, 11 , 15, 20, 23, 31), Mark ratio: 1/2, 1/4, 1/8, 0/8 (172, 3/4, 7/8, 8/8 are possible with logic inversion). Data pattern: Data length: 2 to 8388608 bits; Pattern reset/preset: ALL/PAGE selectable. Alternate pattern: A/B pattern data length: 128 to 4194304 (128 bit steps); Loop time: A, B pattern (1 to 127, 1 steps). Data output; Output waveform: NRZ. Amplitude: 0.25 to 2 Vp-p, 2 mV steps (setting error: ±15% or ±100 mV, whichever is greater). Offset voltage: Voltage: -2 to ±2 V (VOH), 1 mV steps (setting error: ±15% of offset voltage, ±100 mV or ±15% of amplitude whichever is the greatest. Rise/fall time: Typical 30 ps (10% to 90% of amplitude). Pattern jitter: <=20 psp-p (typical 10 psp-p). Waveform distortion: <=15% or <=150 mV whichever is greater



 

Standard Calibration $890.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU MP1763B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Communication Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Data Rate
Data Rate is the maximum number of bits of information which can be transmitted per second, as in a data transmission link. Typically expressed as megabits per second (Mbps).

Optical Signal-to-noise Ratio (OSNR)
Optical Signal-to-noise ratio is the ratio between the signal power and the noise power in a given bandwidth. Most commonly a reference bandwidth of 0.1 nm is used. This bandwidth is independent from the modulation format, the frequency and the receiver. For instance a OSNR of 20dB/0.1nm could be given, even the signal of 40 GBit DPSK would not fit in this bandwidth. OSNR is measured with a Optical Spectrum Analyzer. It is generally measured at the wavelength of interest.

SONET
Synchronous Optical NETwork (SONET) is a fiber-optic transmission system for high-speed digital traffic. Employed by telephone companies and common carriers, speeds range from 51 Mbps to 40 Gbps. SONET is an intelligent system that provides advanced network management and a standard optical interface. Specified in the Broadband ISDN (B-ISDN) standard, SONET backbones are widely used to aggregate T1 and T3 lines. The European counterpart to SONET is the Synchronous Digital Hierarchy, and the term "SONET/SDH" is widely used when referring to SONET


Please contact us for your ANRITSU MP1763B REPAIR and/or ANRITSU MP1763B Pulse Pattern Generator CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: