ILX LIGHTWAVE LDT-5100 CALIBRATION and ILX LIGHTWAVE LDT-5100 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ILX LIGHTWAVE LDT-5100 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another TEC Temperature Controller?
Shop for Comparable Products on our
 used TEC Temperature Controller page

 
   ILX LIGHTWAVE LDT-5100   Description / Specification:    
ILX LIGHTWAVE LDT-5100 2 A / 2 V Temperature Controller

The ILX LDT-5100 offers precise low-noise, high-stability current and temperature control of laser diodes and photodectors. The device is designed especially to meet the needs of critical OEM and other space-constrained applications. Using the resistance of a temperature-dependent thermistor as feedback, the unit stabilizes temperature by driving current to a themoelectric (TE) module. The TE drive of the LDT-5100 is bipolar, allowing for fast settling times whether heating or cooling the load. This allows highly stable temperatures and fast settling times. Desired temperatures are set by adjusting an on-board trimpot to an equivalent thermistor resistance, or by connecting an external reference resistor for an even more precise set point. OutputType: Bipolar, floating, constant current source. Current Range: -2 A to 2 A. Compliance Voltage: , 2VDC.



 

Standard Calibration $405.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ILX LIGHTWAVE LDT-5100. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Chirp
A change in the optical frequency caused by direct modulation of the laser. A chirp is a signal in which the frequency increases ('up-chirp') or decreases ('down-chirp') with time. In some sources, the term chirp is used interchangeably with sweep signal.

Isolation
The extent to which optical power from one signal path is prevented from reaching another signal path.

Polarization Extinction Ratio
Polarization Extinction Ratio is the ratio of optical power in the slow axis of the polarization maintaining fiber to optical power in the fast axis within a specified wavelength range.

Sidemode Suppression Ratio
Sidemode Suppression Ratio is the ratio of average signal power to the optical power of the highest sidemode within a distance from 0.1 to 6 GHz to the signal’s optical frequency, expressed in dB.

Wavelength Stability
Wavelength Stability is the change of wavelength during given time span, expressed as ± half the span between the maximum and the minimum of all actual wavelengths.


Please contact us for your ILX LIGHTWAVE LDT-5100 CALIBRATION and/or ILX LIGHTWAVE LDT-5100 2 A / 2 V Temperature Controller REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: