INSTEK GDM-8034 CALIBRATION and INSTEK GDM-8034 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the INSTEK GDM-8034 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   INSTEK GDM-8034 (GDM8034)   Description / Specification:    
INSTEK GDM-8034 3 1/2 Digit Digital Multimeter

The Instek GDM-8034 Digital Multimeter has a large 0.5" LCD with 3 1/2 digits. It's built-in functions are AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Diode Test, and an Audible Continuity Beeper. Specifications. DC Voltage range: 200 mV, 2 V, 20 V, 200 V, 1000 V. DC Voltage range accuracy: +/- 0.5% of reading + 1 digit. AC Voltage range (40 - 500 Hz): 200 mV, 2 V, 20 V, 200 V, 1000 V. AC Voltage range accuracy: +/- 1% of reading + 4 digit. Resistance range: 200 ohm, 2 K, 20 K, 200 K-ohm, 2 M, 20 M-ohm. DC Current range: 200 uA, 2 mA, 20 mA, 200 mA, 2 A, 20 A. AC Current range (40 - 500 Hz): 200 uA, 2 mA, 20 mA, 200 mA, 2 A, 20 A. Capacitance range: 2 nF, 20 nF, 200 nF, 2 uF, 20 uF. Diode Check Open Voltage: Max 3.2 V. Audible Continuity Check: buzzer sounds if conductance is less than 30 ohm. Sampling Time: 0.4 seconds.



 

Standard Calibration $145.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the INSTEK GDM-8034. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your INSTEK GDM-8034 CALIBRATION and/or INSTEK GDM-8034 3 1/2 Digit Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: