A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEITHLEY 248 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   KEITHLEY 248   Description / Specification:    
KEITHLEY 248 5000V 5mA High Voltage Power Supply

The Keithley 248 High Voltage Supply, designed for use in the laboratory or for test applications, features reversible polarity, excellent regulation, and low output voltage ripple. The digital displays provide accurate readings of voltage and current, and digital entry of current and voltage values allow easy, precise setting of output values. Output voltage can be set from the front panel, via a remote analog voltage, or over the standard IEEE-488 interface. Voltage and current signals are also available for remote monitoring. Specifications. Output Voltage: 0 to ± 5000 V DC. Maximun Output Current: 5.000 mA DC. Voltage set Accuracy: ±(0.01% of setting + 0.05% of range). Voltage Display Accuracy: Voltage Set Accuracy ±1V, typical (±2V, max.). Voltage Resolution: 1V (set and display). Voltage Resettability: 1V. Voltage Limit Range: 0 to 100% of full scale. Voltage Regulation Line: 0.001% for ±10% line voltage change. Voltage Regulation Load: 0.005% for 100% load change, typical. Current Limit Accuracy: 0.01% + 2.5µA. Current Resolution: 1µA. Current Display Accuracy: Current Set Accuracy ±1µA, typ. (±2µA, max.). Stability: ±0.02% per hour typical for ambient temperature within 2°C. Temperature Drift: 50ppm/°C, 0° to 50°C, typical. Monitor Outputs; Output Scale: 0 to +10V for 0 to full range output regardless of polarity. Current Rating: 10mA maximum. Output Impedance: <1ohm. Accuracy: ±0.2% of full scale. Update Rate: 8Hz. External Vlotage Set; Input Scale: 0 to +10V for 0 to full range output regardless of polarity. Input Impedance: 1M-ohm. Accuracy: ±0.2% of full scale. Update Rate: 16Hz. Output Slew Rate: <0.3s for 0 to full range under full load.



 

Standard Calibration $550.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the KEITHLEY 248. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your KEITHLEY 248 CALIBRATION and/or KEITHLEY 248 5000V 5mA High Voltage Power Supply REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: