KEITHLEY 248 CALIBRATION and KEITHLEY 248 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEITHLEY 248 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   KEITHLEY 248   Description / Specification:    
KEITHLEY 248 5000V 5mA High Voltage Power Supply

The Keithley 248 High Voltage Supply, designed for use in the laboratory or for test applications, features reversible polarity, excellent regulation, and low output voltage ripple. The digital displays provide accurate readings of voltage and current, and digital entry of current and voltage values allow easy, precise setting of output values. Output voltage can be set from the front panel, via a remote analog voltage, or over the standard IEEE-488 interface. Voltage and current signals are also available for remote monitoring. Specifications. Output Voltage: 0 to ± 5000 V DC. Maximun Output Current: 5.000 mA DC. Voltage set Accuracy: ±(0.01% of setting + 0.05% of range). Voltage Display Accuracy: Voltage Set Accuracy ±1V, typical (±2V, max.). Voltage Resolution: 1V (set and display). Voltage Resettability: 1V. Voltage Limit Range: 0 to 100% of full scale. Voltage Regulation Line: 0.001% for ±10% line voltage change. Voltage Regulation Load: 0.005% for 100% load change, typical. Current Limit Accuracy: 0.01% + 2.5µA. Current Resolution: 1µA. Current Display Accuracy: Current Set Accuracy ±1µA, typ. (±2µA, max.). Stability: ±0.02% per hour typical for ambient temperature within 2°C. Temperature Drift: 50ppm/°C, 0° to 50°C, typical. Monitor Outputs; Output Scale: 0 to +10V for 0 to full range output regardless of polarity. Current Rating: 10mA maximum. Output Impedance: <1ohm. Accuracy: ±0.2% of full scale. Update Rate: 8Hz. External Vlotage Set; Input Scale: 0 to +10V for 0 to full range output regardless of polarity. Input Impedance: 1M-ohm. Accuracy: ±0.2% of full scale. Update Rate: 16Hz. Output Slew Rate: <0.3s for 0 to full range under full load.



 

Standard Calibration $295.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the KEITHLEY 248. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your KEITHLEY 248 CALIBRATION and/or KEITHLEY 248 5000V 5mA High Voltage Power Supply REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: