KEITHLEY 740 CALIBRATION and KEITHLEY 740 REPAIR

The KEITHLEY 740 is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEITHLEY 740 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Temperature Recording / Thermometer?
Shop for Comparable Products on our
 used Temperature Recording / Thermometer page

 
   KEITHLEY 740   Description / Specification:    
KEITHLEY 740 Scanning Thermometer

The Keithley 740 Programmable Thermometer has a built-in reference junction and will linearize any of seven different thermocouple types. Each input can be selected for any of J, K, T, E, R, S, or B type thermocouples, orforvoltage readback up to 100 mV with 1 uV sensitivity, Any input can also be turned off, allowing the instrument to skip that channel in the scan sequences. Open thermocouple conditions are detected and displayed. A single input can be read at programmable intervals to monitor temperature trends. Rates up to 20 readings/second are available for determining rapid temperature variations, and the data can be stored in the internal memory, Data can also be transferred to a computer file over the built-in IEEE-488 bus, Locate hot spots and examine time-dependent thermal characteristics, Scan intervals are programmable, and the maximum rate of 20 readings/second assures a minimum of time skew between input samples for monitoring temperature changes. A 7402 thermocouple scanner card will add nine channels of thermocouple input. Specifications. Thermocouple temperature measurement: -200° to +1821° C (Thermocouple Dependent). Maximum allowable input: 250V rms, 350V peak (for one minute). Maximum common mode voltage: 200V peak to earth. Maximum thermocouple loop resistance: 1 kohm. Filter setling time: 100 ms (typical). Scanning rate: >20 channels /second, filter disabled; >5 channels /second, filter enabled. Bench reading rate: b readings /second, filter disabled; 4 readings/second, filter enabled. Logging interval: one of 12 selectable rates from 50 ms to 1 hour, or triggered. Scanning interval: one of 10 selectable rates from 500 ms to 1 hour, or triggered. Display: Eight 0.5-inch alphanumeric LED digits with decimal point and polarity. Function, Filter, Channel, Location, Overflow, Open Thermocouple and IEEE bus status also displayed.



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the KEITHLEY 740. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


 

Please contact us for your KEITHLEY 740 CALIBRATION and/or KEITHLEY 740 Scanning Thermometer REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: