LECROY LT344L CALIBRATION and LECROY LT344L REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the LECROY LT344L Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   LECROY LT344L   Description / Specification:    
LECROY LT344L 4 Ch 500 MHz Waverunner LT Digital Oscilloscope

DC to 500 MHz Bandwidth, 4 input channels. Input impedance: 1 M ohm (approx. 12 pF), or 50 ohm ±1%. Trigger Sensitivity: 2 div p-p (DC to 500 MHz). Vertical Voltage axis sensitivity: 2 mV/div to 5 V/div. Horizontal Time axis accuracy: ±(0.01% + 500 ps). Rise Time: 350 ps. Sampling rate; Max: 25 GS/s, Per channel: 500 MS/s. Record length; Max: 1 M words, Per channel: 1 M words. Display, LCD: 8.4-inch TFT, color (810 x 696 pixels).



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the LECROY LT344L. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your LECROY LT344L CALIBRATION and/or LECROY LT344L 4 Ch 500 MHz Waverunner LT Digital Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: