AEMC 1060 CALIBRATION and AEMC 1060 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AEMC 1060 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   AEMC 1060 (2130.03)   Description / Specification:   Spec Sheet 
AEMC 1060 1000V Digital/Analog Insulation Tester

The AEMC 1060 1000V Digital/Analog Insulation Tester is designed to facilitate testing by incorporating automatic measurement features and user friendly functions. The Model 1060 provides test voltage combinations of 50V, 100V, 250V, 500V and 1000V. Measurements are displayed on a large dual-display LCD with bargraph for quick viewing of changes or trends. The AEMC 1060 automatically provides the DAR and PI ratios directly on the display. User defined PI time intervals may also be programmed. The user may even select DAR or PI functions before the test, and the megohmmeter will stop at the appropriate time and display the results. An automatic test inhibitor prevents testing on live circuits above 25V and discharge test voltage may be displayed. A memory feature permits storage, recalling and displaying of resistance values taken at user specified intervals during a test. RS-232 interface to DataView for easy report printing. Specifications. Insulation Test voltage selections: 50V, 100V, 250V, 500V and 1000V. Insulation measurements: to 4000 Gohm (4 Tohm). Insulation Accuracy: 2 kohm to 40 Gohm (5% of Reading ± 3 cts), 40 Gohm to 4 Tohm (±15% of Reading ± 10 cts). Voltage Test/Safety Check: 0 to 1000 Vac/dc. Voltage Warning Indicator: >25V. Test Inhibition: Yes >25V. Resistance Measurement Range: 0.01 ohm to 400 kohm. Resistance Test Voltage: 12.4 Vdc max. Resistance Test Current: <6 mAdc. Resistance Accuracy >4kohm: ±3% of Reading ± 3cts. Continuity Measurement Range: 0.01 to 39.99 ohm. Continuity Test Current: >=200 mA from 0.01 to 20.00 ohm. Continuity Accuracy: ±3% of Reading ± 4 cts. Memory of Reading over Time R(t): Yes (128kB memory). Memory of Test Results in Files: 128kB memory with RS-232.



 

Standard Calibration $245.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AEMC 1060. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your AEMC 1060 CALIBRATION and/or AEMC 1060 1000V Digital/Analog Insulation Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: