AEMC 1050 CALIBRATION and AEMC 1050 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AEMC 1050 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   AEMC 1050 (2130.01)   Description / Specification:   Spec Sheet 
AEMC 1050 1000V Digital/Analog Insulation Tester

The AEMC 1050 1000V Digital/Analog Insulation Tester is designed to facilitate testing by incorporating automatic measurement features and user friendly functions. The Model 1050 provides test voltage combinations of 50V, 100V, 250V, 500V and 1000V. Measurements are displayed on a large dual-display LCD with bargraph for quick viewing of changes or trends. The AEMC 1050 automatically provides the DAR and PI ratios directly on the display. User defined PI time intervals may also be programmed. The user may even select DAR or PI functions before the test, and the megohmmeter will stop at the appropriate time and display the results. An automatic test inhibitor prevents testing on live circuits above 25V and discharge test voltage may be displayed. A memory feature permits storage, recalling and displaying of resistance values taken at user specified intervals during a test. Specifications. Insulation Test voltage selections: 50V, 100V, 250V, 500V and 1000V. Insulation measurements: to 4000 Gohm (4 Tohm). Insulation Accuracy: 2 kohm to 40 Gohm (5% of Reading ± 3 cts), 40 Gohm to 4 Tohm (±15% of Reading ± 10 cts). Voltage Test/Safety Check: 0 to 1000 Vac/dc. Voltage Warning Indicator: >25V. Test Inhibition: Yes >25V. Resistance Measurement Range: 0.01 ohm to 400 kohm. Resistance Test Voltage: 12.4 Vdc max. Resistance Test Current: <6 mAdc. Resistance Accuracy >4kohm: ±3% of Reading ± 3cts. Continuity Measurement Range: 0.01 to 39.99 ohm. Continuity Test Current: >=200 mA from 0.01 to 20.00 ohm. Continuity Accuracy: ±3% of Reading ± 4 cts. Memory of Reading over Time R(t): Yes (20 Readings).



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AEMC 1050. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your AEMC 1050 CALIBRATION and/or AEMC 1050 1000V Digital/Analog Insulation Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: