AEMC 3711 CALIBRATION and AEMC 3711 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AEMC 3711 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   AEMC 3711 (2117.60)   Description / Specification:   Spec Sheet 
AEMC 3711 Clamp-On Ground Resistance Tester

The AEMC 3711 Clamp-on Ground Resistance Tester measures ground rod and small grid resistance through any season, without the use of auxiliary ground rods. Check Resistance on Single and Multiple Rods or Grids. Clamp-on Ground Resistance Testers are used in multi-grounded systems without disconnecting the ground under test. The AEMC 3711 simply clamps around the ground conductor or rod and measures the resistance to ground. By performing measurements on intact ground systems, the user also verifies the quality of the grounding connections and bonds. Resistance and continuity of grounding loops around pads and buildings may also be measured. Specifications. Ground Resistance Measurement Range: Autoranging 0.01 to 1200 ohm. Ground Resistance Resolution: 0.01 ohm (0.1 to 1.0 ohm), 0.1 ohm (1.0 to 50.0 ohm), 0.5 ohm (50.0 to 100.0 ohm), 1 ohm (100 to 200 ohm), 5 ohm (200 to 400 ohm), 10 ohm (400 to 600 ohm), 50 ohm (600 to 1200 ohm). Ground Resistance Accuracy: ± (2% + 0.02 ohm) (0.1 to 1.0 ohm), ± (1.5% + 0.1 ohm) (1.0 to 50.0 ohm), ± (2.0% + 0.5 ohm) (50.0 to 100.0 ohm), ± (3.0% + 1 ohm) (100 to 200 ohm), ± (6.0% + 5 ohm)(200 to 400 ohm), ± (10% + 10 ohm) (400 to 600 ohm), 25% of Reading ±50 ohm (600 to 1200 ohm). Resistance Measurement Frequency: 2403 Hz. Ground or Leakage Current: Autoranging 1 mA to 30.00 Arms. Current Measurement Frequency: 47 to 800 Hz. Current Overload: OL displayed above 29.99 Arms.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AEMC 3711. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your AEMC 3711 CALIBRATION and/or AEMC 3711 Clamp-On Ground Resistance Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: