SORENSEN DCR20-25B CALIBRATION and SORENSEN DCR20-25B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the SORENSEN DCR20-25B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   SORENSEN DCR20-25B   Description / Specification:    
SORENSEN DCR20-25B 20V 25A Single Output DC Power Supply

The Sorenson DCR20-25B Power Supply incorporates a single phase input SCR controlled regulator providing high efficiency and fully adjustable output power. It has excellent voltage and current regulation with automatic crossover. Features. Panel lights indicate operating mode. Remote voltage and resistance programming in voltage and current modes. Adjustable current limiting (overload/short circuit protection) with automatic recovery. Overvoltage protection standard. Specifications. Output Voltage: 0 to 20 Vdc. Output Current (40 C): 25 A. Constant Voltage Regulation: 10 mV. Constant Current Regulation: 63 mA. Constant Voltage Ripple (PARD): 65 rms/mV. Constant Current Ripple (PARD): 82 rms/mA. Voltage Regulation (Constant Voltage Mode): 0.05% or 10 mV, whichever is greater. Temperature Coefficient: 0.015%/C of Eo max. Stability: 0.1% Eo max for 8 hours after 30 minute warm-up. Remote Sensing: Maximum drop per load lead should not exceed 5% of Eo max. or 3 V, whichever is smaller. Transient Response: 50 ms (typical) to return to ± 2% band for step load change of 50 to 100% of full load. Current Regulation (Constant Current Mode): 0.25% of 10 max. line and load combined. Temperature Coefficient: 0.03%/C. of lo max. Stability: 0.15% of 10 max. for 8 hours after 30 minute warm-up.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the SORENSEN DCR20-25B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your SORENSEN DCR20-25B CALIBRATION and/or SORENSEN DCR20-25B 20V 25A Single Output DC Power Supply REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: