SORENSEN DCR40-13B CALIBRATION and SORENSEN DCR40-13B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the SORENSEN DCR40-13B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   SORENSEN DCR40-13B   Description / Specification:    
SORENSEN DCR40-13B 40V 13A Single Output DC Power Supply

The Sorenson DCR40-13B Power Supply incorporates a single phase input SCR controlled regulator providing high efficiency and fully adjustable output power. It has excellent voltage and current regulation with automatic crossover. Features. Panel lights indicate operating mode. Remote voltage and resistance programming in voltage and current modes. Adjustable current limiting (overload/short circuit protection) with automatic recovery. Overvoltage protection standard. Specifications. Output Voltage: 0 to 40 Vdc. Output Current (40 C): 13 A. Constant Voltage Regulation: 20 mV. Constant Current Regulation: 33 mA. Constant Voltage Ripple (PARD): 90 rms/mV. Constant Current Ripple (PARD): 30 rms/mA. Voltage Regulation (Constant Voltage Mode): 0.05% or 10 mV, whichever is greater. Temperature Coefficient: 0.015%/C of Eo max. Stability: 0.1% Eo max for 8 hours after 30 minute warm-up. Remote Sensing: Maximum drop per load lead should not exceed 5% of Eo max. or 3 V, whichever is smaller. Transient Response: 50 ms (typical) to return to ± 1% band for step load change of 50 to 100% of full load. Current Regulation (Constant Current Mode): 0.25% of 10 max. line and load combined. Temperature Coefficient: 0.03%/C. of lo max. Stability: 0.15% of 10 max. for 8 hours after 30 minute warm-up.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the SORENSEN DCR40-13B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your SORENSEN DCR40-13B CALIBRATION and/or SORENSEN DCR40-13B 40V 13A Single Output DC Power Supply REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*