SORENSEN DCR60-30B CALIBRATION and SORENSEN DCR60-30B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the SORENSEN DCR60-30B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   SORENSEN DCR60-30B   Description / Specification:    
SORENSEN DCR60-30B 60V 30A Single Output DC Power Supply

The Sorenson DCR60-30B Power Supply incorporates a single phase input SCR controlled regulator providing high efficiency and fully adjustable output power. It has excellent voltage and current regulation with automatic crossover. Features. Panel lights indicate operating mode. Remote voltage and resistance programming in voltage and current modes. Adjustable current limiting (overload/short circuit protection) with automatic recovery. Overvoltage protection standard. Specifications. Output Voltage: 0 to 60 Vdc. Output Current (40 C): 30 A. Constant Voltage Regulation: 30 mV. Constant Current Regulation: 75 mA. Constant Voltage Ripple (PARD): 125 rms/mV. Constant Current Ripple (PARD): 63 rms/mA. Voltage Regulation (Constant Voltage Mode): 0.05% or 10 mV, whichever is greater. Temperature Coefficient: 0.015%/C of Eo max. Stability: 0.1% Eo max for 8 hours after 30 minute warm-up. Remote Sensing: Maximum drop per load lead should not exceed 5% of Eo max. or 3 V, whichever is smaller. Transient Response: 50 ms (typical) to return to ± 1% band for step load change of 50 to 100% of full load. Current Regulation (Constant Current Mode): 0.25% of 10 max. line and load combined. Temperature Coefficient: 0.03%/C. of lo max. Stability: 0.15% of 10 max. for 8 hours after 30 minute warm-up.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the SORENSEN DCR60-30B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your SORENSEN DCR60-30B CALIBRATION and/or SORENSEN DCR60-30B 60V 30A Single Output DC Power Supply REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: