SORENSEN DCS60-50 CALIBRATION and SORENSEN DCS60-50 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the SORENSEN DCS60-50 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   SORENSEN DCS60-50   Description / Specification:    
SORENSEN DCS60-50 60V 50A Single Output DC Power Supply

The Sorensen DCS60-50 programmable power supply incorporates current mode switching rates up to 100 kHz in high power density, low profile packages. Utilizing state-of-the-art technology and unique packaging techniques, the DCS60-50 provides continuous full output power in any volt/amp combination within the rated output voltage and current limits. Options include an internal IEEE-488/RS-232 interface and isolated analog programming of voltage or current. Specifications. Output Voltage: 0 to 60 V. Output Current: 0 to 50 A. Regulation Line and Load: 0.2%. Constant Voltage Mode Ripple (PARD): 20 mV rms. Constant Voltage Mode Resolution: 0.02%. Constant Voltage Mode Transient Response Time (Typ.): 500 µs. Temperature Coefficient Voltage (Typ.): 0.02 % C. Voltage Drift (Typ.): 0.05% V max. Constant Current Mode Regulation Line and Load: 0.2%. Constant Current Mode Ripple (PARD): 33 mA rms. Constant Current Mode Resolution (Typ.): 0.02%. Temperature Coefficient Current (Typ.): 0.03 % C. Current Drift (Typ.): 0.05% V max. Transient Response: < 1 ms recovery to 1 % band for 30% step load change (70- 100% or 100-70%) 500 µs typical. Stability: 0. 5% drift max over 8 hrs. with constant line, load and temperature, following 20 minute warm-up. Options. M51: Isolated programming control of either the output current or voltage using analog signals that can be biased up to 600V relative to the supply's return line. M85: Slave multichannel interface control.



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the SORENSEN DCS60-50. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your SORENSEN DCS60-50 CALIBRATION and/or SORENSEN DCS60-50 60V 50A Single Output DC Power Supply REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: