TEKTRONIX 370A REPAIR and TEKTRONIX 370A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the TEKTRONIX 370A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX 370A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Semiconductor Tester?
Shop for Comparable Products on our
 used Semiconductor Tester page

 
   TEKTRONIX 370A   Description / Specification:    
TEKTRONIX 370A Programmable Curve Tracer

The Tektronix 370A Programmable Curve Tracer provides DC parameter characterization of transistors, thyristors, diodes, SCRs, MOSFETs, optoelectronic components, solar cells, solid state displays and other semiconductor devices. After completing the characterization definition, interactive settings can be stored in the curve tracer's memory, disk or an external controller. Collector Supply Modes: AC, ±DC, ± Leakage, ±Rectified Sine. Collector Supply Range: 16 to 2000V, 0.05 to 10 A. Step Generator Modes: Stair step: DC, 80 usec pulse, 300 usec pulse. Step Range: Current: 50 nA to 200 mA in 1-2-5 sequence. Voltage: 50 mV to 2 V in 1-2-5 sequence. Offset: Up to ± 10X step amplitude. No. of steps: 0 to 10. Measurement Characteristics; Collector Current: Measurement range: 100 nA/div (1 nA resolution) to 2 A/div. Accuracy: 1.5% of cursor readout +0.05 div of setting (with dot cursor). Emitter Current Measurement range: 1 nA/div (10 pA resolution) to 2 mA/div. Accuracy: 1.5% of cursor readout + 0.05 div of setting + 1 nA.



 

Standard Calibration $980.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX 370A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your TEKTRONIX 370A REPAIR and/or TEKTRONIX 370A Programmable Curve Tracer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: