TEKTRONIX 7A29 CALIBRATION and TEKTRONIX 7A29 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX 7A29 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   TEKTRONIX 7A29   Description / Specification:    
TEKTRONIX 7A29 Wideband Single-trace Amplifier Plug-in

The Tektronix 7A29 is a Dc to 1 GHz, High-performance, wide-bandwidth, single-trace amplifier, is designed primarily for use with the7100, 7700-, 7800-, and 7900-Series Mainframes. Bandwidth is constant over the entire range of calibrated deflection sensitivities of 10 mV to 1 Vldiv. Input impedance is 50 ohm. Manually resettable input-protection circuitry protects the input against most common overloads. Polarity of the display is selectable by a front-panel switch. An optional variable delay line (front-panel adjustable) permits matching the transit time of two 7A29s and/or probes to better than 10 ps. The 7A29 has a 10 mV/ div to 1 V/ div vertical sensitivity. Deflection Factor-10 mV/div to 1 V/div in 7 calibrated steps (1-2-5 sequence). Accuracy is within 2% with gain adjusted at 0.1 V/div. Uncalibrated variable is continuous between steps to at least 2.5 V/div. Input R - 50 ohm. Option 04, Variable Signal Delay - Permits matching the transit time of two preamps and probes to better than 10 ps, Range is 1 ns. Max Input- 10 V RMS or 1 W-second pulses not exceeding 50 V peak in dc coupled mode. 100 V dc additional in ac coupled mode.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX 7A29. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your TEKTRONIX 7A29 CALIBRATION and/or TEKTRONIX 7A29 Wideband Single-trace Amplifier Plug-in REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: