TEKTRONIX 7B10 CALIBRATION and TEKTRONIX 7B10 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX 7B10 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   TEKTRONIX 7B10   Description / Specification:    
TEKTRONIX 7B10 Horizontal Time Base Plug-in

Horizontal time base designed for use with the 7104 Mainframe to provide optimum bandwidth/ sweep-speed compatibility, but may also be used with the 7700, 7800, and 7900 Series Mainframes. Features: 0.2 ns/div to 0.5/div Calibrated Time Bases. Triggering to 1 GHz. Variable Trigger Holdoff. Peak-to-Peak Auto Triggering. Sweep Rates - 0.2 s/div to 2 ns /div in 25 steps. 10X MAGNIFIER extends fastest calibrated sweep rate to 0.2 ns/div. The uncalibrated VARIABLE is continuous to at least 2.5 times the calibrated sweep. Trace Separation Range - Funclional only in Delta Delay Time mode when alternating or chopping between time-base units. The second delayed sweep display can be vertically positioned at least 3 div below the first delayed sweep display. Delay Time Range - 0.2 or less to at least 9.0 times TIME/ DIV setting. Jitter - 0.02% of TIME/ DIV setting up through 50 us/ div. 0.03% of TIME/ DIV setting plus 0.1 ns for sweep speeds of 20 us/div through 100 ns /div. External Trigger Input - Max input voltage is 250 V (dc + peak ac) for 1 M-Ohm input 1 W average for 50 ohm input. Input R and C for 1 M-Ohm Input is 1 M-Ohm within 5%, 20 pf within 10%; for 50 ohm input, 50 ohm within 2%. Level range is at least ± 3.5 V in EXT + 1.



 

Standard Calibration $330.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX 7B10. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your TEKTRONIX 7B10 CALIBRATION and/or TEKTRONIX 7B10 Horizontal Time Base Plug-in REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: