TEKTRONIX AA501 CALIBRATION and TEKTRONIX AA501 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX AA501 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   TEKTRONIX AA501   Description / Specification:    
TEKTRONIX AA501 Distortion Analyzer Plug-In

The Tektronix AA501 Distortion Analyzer Plug-In provides measurement of level, total harmonic distortion plus noise (THD+N). The fundamental frequency range is 10Hz to 100kHz, with harmonics measured out to 300kHz. The distortion ranges are auto (100%), 20%, 2%, 0.2%, and dB (autoranging). The unit allows readings to be expressed in true rms or average response and rms calibrated. Any one of four built-in frequency-weighting filters may be switched into the signal paths for preconditioning of the signal to be measured. Provision is also made to permit the use of a user-selected filter as well. The digital voltmeter has input range of 200 µV to 200 V (10 steps) plus auto range and will display signal level in volts, dBm, or dB ratio. Other features include input monitor, function output, and auxiliary input connectors. It utilizes 2 slots in a Tek TM-Series Power Module.



 

Standard Calibration $635.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX AA501. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your TEKTRONIX AA501 CALIBRATION and/or TEKTRONIX AA501 Distortion Analyzer Plug-In REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: