TEKTRONIX CDM250 CALIBRATION and TEKTRONIX CDM250 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX CDM250 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   TEKTRONIX CDM250   Description / Specification:    
TEKTRONIX CDM250 3 1/2 Digit Digital Multimeter

The Tektronix CDM250 Digital Multimeter, 3 1/2 digit LED display. AC/DC Volts (500 V Range) Resistance (20 mega ohm Range). Current (10 A Range). DCA Voltage Ranges - 200A mV, 2A V, 20A V, 200A V, 500A V. Basic DCA Volts Accuracy - A ±(0.5% of reading +1A count). Max DC InputA Voltage - 500A VDC (DC +A peakA AC). ACA Voltage Ranges - 200A mV, 2A V, 20A V, 200A V, 500A V. Basic ACA Volts Accuracy - A ±(1.0% of reading +4A counts). Max AC InputA Voltage - 350A VACRMS; 500A V (DC + peak AC). DC Current Ranges - 200 AµA, 2A mA, 20A mA, 200A mA, 2 A, 10 A. Basic DC Current Accuracy - A±(1.0% of reading +1A count). Max DC Input Current - 2 A fused, 10 A unfused. AC Current Ranges - 200 AµA, 2A mA, 20A mA, 200A mA, 2 A, 10 A. Basic AC Current Accuracy - A ±(1.5% of reading +4A counts). Max AC Input CurrentA Voltage - 650A V pk, current input to common. Resistance Ranges - 200A Ohm, 2 kilohm, 20 kilohm, 200 kilohm, 2 megaohm, 20 megaohm. Basic Resistance Accuracy - A±(0.75% of reading +1A count). Max Resistance InputA Voltage - 500A V (DC)



 

Standard Calibration $450.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX CDM250. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your TEKTRONIX CDM250 CALIBRATION and/or TEKTRONIX CDM250 3 1/2 Digit Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: