TEKTRONIX DC5010 CALIBRATION and TEKTRONIX DC5010 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX DC5010 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Frequency Counter? Shop for Comparable Products on our   new Frequency Counter page

 
   TEKTRONIX DC5010   Description / Specification:    
TEKTRONIX DC5010 Programmable Universal Counter / Timer Plug-in

The Tektronix DC 5010 Programmable Universal Counter / Timer features reciprocal frequency to 350 MHz, period, ratio, events B during A measurements, and time A to B. The powerful reciprocal technique provides high resolution of low frequency signals much faster than conventional counting techniques. The pseudo-random, phase-modulated time base provides increased accuracy by eliminating synchronous errors in the time interval and width averaging modes. Auto trigger senses the applied signal and sets trigger levels to the optimum points. In the DC 5010, trigger levels, the minimum and maximum signal voltage levels, and the trigger voltage are available over the GPIB, and can be viewed on the 9-digit display. Channel A and Channel B Input; Frequency Range - 50 ohm termination: >0 to >= 350 MHz DC coupled. 100 kHz to >= 350 MHz AC coupled. 1 M-ohm termination > 0 to >= 300 MHz DC coupled. 16 Hz to >= 300 MHz AC coupled. Sensitivity - 50 ohm termination DC: <= 25 mV RMS sinewave to 350 MHz <= 70 mV p-p pulse 1 M-ohm termination. DC/AC <= 25 mV RMS to 200 MHz. 42 mV RMS to 300 MHz. Attenuation Selectable - 1X, 5X. Impedance - 1 M-ohm paralleled by 23 pf ±2.2 pF (10%) or 50 ohm ±3% DC. Dynamic Range - 70 mV p-p to 4 V p-p (x attenuation). Trigger Level Range - >= + 2 V to <= - 2 V with 4 mV resolution (X1). <= ±10 V to <= -10 V with 20 mV resolution (X5). Trigger Level Accuracy - ±1 % of F.S. trigger level range, plus ±2% of reading for a DC input V, ±40 mV X Attenuator. Autotrigger Frequency Range - 10Hz to <= 350 MHz. Independent Controls - Slope, Attenuation 1X / 5X, Couple AC/DC, Impedance 1 M-ohm / 50 ohm. Frequency A Range: <= 36 uHz to >= 350 MHz. Accuracy Resolution: ±(Time Base Error x Frequency A). Rise / fall A Range - 5.0 ns to 7.6 hrs.



 

Standard Calibration $345.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX DC5010. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your TEKTRONIX DC5010 CALIBRATION and/or TEKTRONIX DC5010 Programmable Universal Counter / Timer Plug-in REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: