TEKTRONIX DC509 CALIBRATION and TEKTRONIX DC509 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX DC509 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Frequency Counter? Shop for Comparable Products on our   new Frequency Counter page

 
   TEKTRONIX DC509   Description / Specification:    
TEKTRONIX DC509 Universal Counter / Timer Plug-in

The Tektronix DC 509 single-width Universal Counter / Timer provides all of the measurement functions of the higher performance DC 5010/ DC 510 except rise time/fall time, null, and totalize A ± B. The powerful reciprocal-frequency measurement technique allows up to eight digits of resolution of low-frequency signals in one second or less of measurement time. The DC 509 has the same automatic averaging feature as the DC 5010/ DC 510; selected averaging of up to 108 events provides usable time-interval resolution of 5 ps. Channel A and Channel B Input; Frequency Range - >0 to >= 135 MHz DC coupled. <= 10 Hz to >= 135 MHz AC coupled. Sensitivity - <= 20 mV RMS (56.6 mV p-p) to >= 100 MHz, 40 mV RMS (113 mVp-p) from 100 MHz to >= 135 MHz, 115 mV p-p at minimum, pulse width of 3 ns. Attenuation Selectable - 1X, 5X. Impedance - 1 M-ohm ±2% paralleled by <= 30 pF. Trigger Level Range - +3.200 to -3.175 V with 25 mV resolution (X1), + 16 to -15.875 V with 125 mV resolution (x5). Trigger Level Accuracy - ±15 mV ±40 uV/°C referenced to 25°C. Dynamic Range - 3.2 <= input voltage <= +3.2 . X1: Vin p-p <= 3 V; X5: Vp-p 15 Vin (for input signal risetime p-p <= 3 V; X5: Vp-p 15 Vin); (for input signal risetimes <= 5 ns). Autotrigger Frequency Range - Sensitivity <= 125 mV p-p x attenuation; <= 20 Hz to >= 100 MHz. Range: ±3.2 V x attenuation. Resolution: 25 mV x attenuation. Independent Controls - Slope ±, attenuation 1X / 5X, Couple AC/DC, Source Internal/External. Frequency A Range: <= 100 uHz to >= 135 MHz. Accuracy Resolution: ±(Time Base Error x Frequency A). Rise / fall A Range - 7.4 ns to 3.05 hrs.



 

Standard Calibration $115.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX DC509. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your TEKTRONIX DC509 CALIBRATION and/or TEKTRONIX DC509 Universal Counter / Timer Plug-in REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: