TEKTRONIX PS501-1 CALIBRATION and TEKTRONIX PS501-1 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX PS501-1 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   TEKTRONIX PS501-1   Description / Specification:    
TEKTRONIX PS501-1 Dual Output Power Supply Plug-In

The Tektronix PS 501-1 Dual Output Power Supply Plug-In out can be digitally displayed on the digital multimeter through this rear connector. A convenience when testing or measuring, the rear interface capability allows the engineer to accurately look at his voltage requirements. The TM 500 power supplies provide up to two independent voltages from one plug-in instrument. And each features a fixed 5-volt-at-1- amp supply for logic circuits or indicators plus one variable supply. For accurate setting and adjustment of the output voltage, our PS 501-1 precision supply features a multiturn potentiometer with mechanical digital readout. Fixed Output + 5 V, 1 A. Floating Output: 0-20 V. Current Limit: < 40 to 400 mA. Line Regulation: Within 5 mV for a ± 10% line voltage change. Load Regulation: Within 1 mV with a 400 mV load change. Ripple and Noise: 0.5 mV p-p or less; 0.1 mV rms or less. Temperature Coefficient: 0.01 %/C or less. Minimum Resolution: 1.6 mV. Voltage is selectable within 0.5% by a 10 turn potentiometer with a 3 digit in-line dial and range switch. Transient Recovery Time: 20 uS or less for a constant voltage to recover within 20 mV of nominal output voltage after a 400 mA change in output current. Requires TM-Series Power Module



 

Standard Calibration $290.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX PS501-1. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your TEKTRONIX PS501-1 CALIBRATION and/or TEKTRONIX PS501-1 Dual Output Power Supply Plug-In REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: