TEKTRONIX PS501-1 CALIBRATION and TEKTRONIX PS501-1 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX PS501-1 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   TEKTRONIX PS501-1   Description / Specification:    
TEKTRONIX PS501-1 Dual Output Power Supply Plug-In

The Tektronix PS 501-1 Dual Output Power Supply Plug-In out can be digitally displayed on the digital multimeter through this rear connector. A convenience when testing or measuring, the rear interface capability allows the engineer to accurately look at his voltage requirements. The TM 500 power supplies provide up to two independent voltages from one plug-in instrument. And each features a fixed 5-volt-at-1- amp supply for logic circuits or indicators plus one variable supply. For accurate setting and adjustment of the output voltage, our PS 501-1 precision supply features a multiturn potentiometer with mechanical digital readout. Fixed Output + 5 V, 1 A. Floating Output: 0-20 V. Current Limit: < 40 to 400 mA. Line Regulation: Within 5 mV for a ± 10% line voltage change. Load Regulation: Within 1 mV with a 400 mV load change. Ripple and Noise: 0.5 mV p-p or less; 0.1 mV rms or less. Temperature Coefficient: 0.01 %/C or less. Minimum Resolution: 1.6 mV. Voltage is selectable within 0.5% by a 10 turn potentiometer with a 3 digit in-line dial and range switch. Transient Recovery Time: 20 uS or less for a constant voltage to recover within 20 mV of nominal output voltage after a 400 mA change in output current. Requires TM-Series Power Module



 

Standard Calibration $290.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX PS501-1. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your TEKTRONIX PS501-1 CALIBRATION and/or TEKTRONIX PS501-1 Dual Output Power Supply Plug-In REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: