TEKTRONIX PS503A CALIBRATION and TEKTRONIX PS503A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX PS503A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   TEKTRONIX PS503A   Description / Specification:    
TEKTRONIX PS503A Triple Output Power Supply Plug-In

The Tektronix PS 503A Triple Output Power Supply Plug-In provides a dual - 20 to 0 and 0 to + 20 volt variable supply plus a 5 volt 1 A independent supply. And you can vary its - 20 and +20 volt supplies in a tracked mode, or set each individually. In the tracking mode, varying the plus and minus supplies in proportion to the voltage ratio set on their individual controls, is a simple, one-knob operation. In the nontracking mode, you can set each supply independently to any voltage - from 0 to 20 V. Output Voltage/Current #1: +5 V at 1 A. Output Voltage/Current #2: 0 to +20 V (1 amp max.). Output Voltage/Current #3: 0 to -20 V (1 amp max.). Current #2 or #3 1A in high-power compartment of TM504 or TM506 or 400 mA in any standard mainframe compartment. Outputs can be varied independently or at a constant ratio. Tracking Mode Offset Error: If the two supplies are set independently to any given vo ltage ratio and then varied by use of the VOLTS DUAL TRACKING control, the two supplies will maintain the same voltage ratio as initially set within ±50 mV. Current Limit: Adjustable from less than 100 mA to 1 A (high-power compartment) or less than 40 mA to 400 mA (standard compartment) on each supply. Load Regulation: Within 3 mV for 1 A change (highpower compartment) or 1 mV for 400 mA change (standard compartment). Ripple and Noise: 3 mV p-p or less at 1 A load (high-power compartment). 0.5 mV p-p or less at 400 mA load (standard compartment). Indicators: Individual voltage indi cators and current limiting indicators for both + and - supplies. Non-high-power compartment (400 mA) indicator. Requires TM-Series Power Module



 

Standard Calibration $690.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX PS503A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your TEKTRONIX PS503A CALIBRATION and/or TEKTRONIX PS503A Triple Output Power Supply Plug-In REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: