TEKTRONIX SD24 REPAIR and TEKTRONIX SD24 CALIBRATION

The TEKTRONIX SD24 is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
Custom-Cal has a high success rate in the repair of the TEKTRONIX SD24. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX SD24 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   TEKTRONIX SD24 (SD-24)   Description / Specification:    
TEKTRONIX SD24 Dual-channel TDR / Sampling Head

The Tektronix SD24 is a dual-channel TDR/Sampling Head. This sampling head has a rise time of 17.5 ps or less, with a typical 20 GHz equivalent-time bandwidth. The input impedance of the SD24 is 50 ohms, and the maximum safe input voltage is ±3 V. The SD24 can be inserted into an 11801, 11802, SM11, or they can be attached to Sampling Head Extender Cables. Each channel of the SD24 is also capable of generating a TDR pulse. The TDR pulse is a fast-rising step that is activated when the SD24 is in TDR mode. Each TDR pulse is applied to the input signal path for that channel. The acquisition portion of the sampling head is still functional for monitoring the incident pulse and this pulse's reflected components. The polarity of each channel's TDR pulse can be selected independently of the other channel. This allows for differential or common-mode testing of two coupled lines, besides independent testing of isolated lines.
Specifications.

Dot Transient Response: Adjustable to ±5% for signals from 0 to 0.5 V p-p; adjustable to unity for signals from 0.5 V to 1.0 V p-p.
Input Termination: 50 ±0.5 ohm.
Displayed Noise: With unity dot response typically 1.3 mV RMS; with smoothing: typically 0.6 mV RMS.
Max (Nondestructive) Input Voltage: ± 3.0 V.
Rise Time: <=17.5 ps.
Bandwidth: >= 20 GHz typical.
Time Coincidence Between Channels: <=10 ps.
Dynamic Range:1 V p-p within a ±1.6 V range.
Displayed Incident Rise Time: <= 28 ps, typical.
Displayed Reflected Rise Time: <= 35 ps.
TDR Pulse Amplitude: Adjustable to ±250 mV (polarity of either pulse may be inverted).
Time Coincidence Between TDR Pulses: Adjustable to less than 1.5 ps.



 

Standard Calibration $540.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX SD24. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your TEKTRONIX SD24 REPAIR and/or TEKTRONIX SD24 Dual-channel TDR / Sampling Head CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: