TEKTRONIX TDS524A REPAIR and TEKTRONIX TDS524A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the TEKTRONIX TDS524A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX TDS524A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX TDS524A   Description / Specification:    
TEKTRONIX TDS524A 4-Ch 500 MHz Digitizing Oscilloscope

The Tektronix TDS524A 500 MHz Digitizing Oscilloscope. Specifications. Channels: 2 + 2 auxiliary. Max Sample Rate. 500 MS/s (Single channel). DC Gain Accuracy - ± 1.0%; Vertical Resolution - 8 bits (256 leve ls over 10.24 vertical divisions). Analog Bandwidth Selections - 20 MHz, 100 MHz, and full (Except Aux 1 and Aux 2 are full BW only). Input Coupling - AC, DC or GND. Input Impedance Selections - 1 M-ohm in parallel with 10 pF, or 50 ohm (AC and DC coupling) . Maximum Input Voltage - ±400 V (DC + peak AC). Derate at 20 dB/decade above 1 MHz, 1 M-ohm or GND coupled. Channel Isolation - > 100:1 at 100 MHz and >30:1 at bandwidth for any two channels having equal Volts/div settings. AC Coupled Low Frequency Limit - <= 10 Hz when AC 1 M-ohm coupled. <= 200 kHz when AC 50 ohm coupled. Time Bases - Main, Delayed. Time/Division Range - 500 ps to 10 s/div. Time Base Accuracy - ± 25 ppm over any interval >= 1 ms. Record Length - 500 to 15,000 pts (50K pts optional). Triggers - Main, Delayed. Main Trigger Modes - Auto, Normal, Single. Time Delay Range - 16 ns to 250 s (time/div <= 10 us); 15.1 ns to 250 s (time/div >=25 us). Color CRT, 7 in. liquid crystal full-color shutter with 256 levels.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX TDS524A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your TEKTRONIX TDS524A REPAIR and/or TEKTRONIX TDS524A 4-Ch 500 MHz Digitizing Oscilloscope CALIBRATION

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: