Keysight (Agilent) N5763A CALIBRATION and Keysight (Agilent) N5763A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) N5763A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   Keysight (Agilent) N5763A   Description / Specification:    
Keysight (Agilent) N5763A Single-Output Switching Regulated DC Power Supply

The Agilent N5763A is a switching regulated, single-output programmable DC power supply. It provides stable output power, built-in voltage and current measurement. The N5763A provides up to 1500 W in a small space-saving 1U high, 19-inch wide package. Its air vents are in the front, side and rear (not on the top or bottom), so you can stack other instruments directly above or below it to save valuable rack space. It has a universal AC input so they can be automatically operated from any AC mains input worldwide. They can be operated from line voltages of 85 – 265 VAC, 47 to 63 Hz, with no switch to set or fuses to change when you switch from one voltage standard to another. They also provide power factor correction. To safeguard your device from damage, the Agilent N5763A power supply provides over-temperature, over-current and over-voltage protect (OVP) to shut down the power supply output when a fault occurs. They also offer an undervoltage limit (UVL) that prevents adjustment of the output voltage below a certain limit. The combination of UVL and OVP capabilities lets you create a protection window for sensitive load circuitry. Should you need greater output power, the N5763A power supply gives you the flexibility to connect in parallel up to four similarly rated units for greater output current and connect two similarly rated units in series for greater output voltage (see DC float voltage information). Specifications. Voltage: 12.5 V. Current: 120 A. Power: 1500 W. Programming accuracy Voltage: 0.05%+ 6.25 mV. Programming accuracy Current: 0.1%+ 120 mA. Output ripple and noise CV p-p (Up to 20 MHz): 60 mV. Output ripple and noise CV rms (From 5 Hz – 1 MHz): 8 mV. Readback accuracy Voltage: 0.1%+ 12.5 mV. Readback accuracy Current: 0.1%+ 360 mA. Load regulation (change from 10% to 90%): Voltage 3.25 mV / Current 29 mA. Transient response time: <= 1.5 ms. DC floating voltage: No output terminal may be more than ±60 VDC from any other terminal or chassis ground. I/O interface: GPIB, LAN, USB standard.



 

Standard Calibration $115.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) N5763A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your Keysight (Agilent) N5763A CALIBRATION and/or Keysight (Agilent) N5763A Single-Output Switching Regulated DC Power Supply REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: