Keysight (Agilent) N5764A CALIBRATION and Keysight (Agilent) N5764A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) N5764A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   Keysight (Agilent) N5764A   Description / Specification:    
Keysight (Agilent) N5764A Single-Output Switching Regulated DC Power Supply

The Agilent N5764A is a switching regulated, single-output programmable DC power supply. It provides stable output power, built-in voltage and current measurement. The N5764A provides up to 1520 W in a small space-saving 1U high, 19-inch wide package. Its air vents are in the front, side and rear (not on the top or bottom), so you can stack other instruments directly above or below it to save valuable rack space. It has a universal AC input so they can be automatically operated from any AC mains input worldwide. They can be operated from line voltages of 85 – 265 VAC, 47 to 63 Hz, with no switch to set or fuses to change when you switch from one voltage standard to another. They also provide power factor correction. To safeguard your device from damage, the N5764A power supply provides over-temperature, over-current and over-voltage protect (OVP) to shut down the power supply output when a fault occurs. They also offer an undervoltage limit (UVL) that prevents adjustment of the output voltage below a certain limit. The combination of UVL and OVP capabilities lets you create a protection window for sensitive load circuitry. Should you need greater output power, the Agilent N5764A power supply gives you the flexibility to connect in parallel up to four similarly rated units for greater output current and connect two similarly rated units in series for greater output voltage (see DC float voltage information). Specifications. Voltage: 20 V. Current: 76 A. Power: 1520 W. Programming accuracy Voltage: 0.05%+ 10 mV. Programming accuracy Current: 0.1%+ 76 mA. Output ripple and noise CV p-p (Up to 20 MHz): 60 mV. Output ripple and noise CV rms (From 5 Hz – 1 MHz): 8 mV. Readback accuracy Voltage: 0.1%+ 20 mV. Readback accuracy Current: 0.1%+ 228 mA. Load regulation (change from 10% to 90%): Voltage 4 mV / Current 20.2 mA. Transient response time: <= 1.5 ms. DC floating voltage: No output terminal may be more than ±60 VDC from any other terminal or chassis ground. I/O interface: GPIB, LAN, USB standard.



 

Standard Calibration $115.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) N5764A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your Keysight (Agilent) N5764A CALIBRATION and/or Keysight (Agilent) N5764A Single-Output Switching Regulated DC Power Supply REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: