NEWPORT 3150 CALIBRATION and NEWPORT 3150 REPAIR

The NEWPORT 3150 is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the NEWPORT 3150 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another TEC Temperature Controller?
Shop for Comparable Products on our
 used TEC Temperature Controller page

 
   NEWPORT 3150   Description / Specification:    
NEWPORT 3150 350 Watt Temperature Controller

The Newport 3150 Temperature Controller is a precision thermoelectric cooler controller. It is Operational with most thermistors, IC and RTD temperature sensors. A high power 7W2 female D-connector is used for input and output connections. Specifications. TEC Output; Maximum Current / Voltage: 15 Amps at 23 Volts or 12.5 Amps at 28 Volts. Maximum Power: 350 Watts. TE Current Resolution: 0.458 mA. TE Current Accuracy (mA): ± (3 % set point + 50 mA). Current Limit Range: 0 to 15 Amps. Accuracy: ± 150 mA. Ripple/Noise (rms): < 10 mA. Short Term Stability (1 hour): < 0.0005 °C. Long Term Stability (24 hour): < 0.001 °C. Temperature Coefficient (°C/°C): < 0.05. Display Range Temperature: -100.00°C to +240.00°C. Display Range Resistance (10 µA) 0.01 k-ohm to 495.000 k-ohm. Display Range TE Current: ± 15.00 Amps. Display Range TE Voltage: 0.0 to 30.0 Volts. Resolution Temperature: 0.01°C. Resolution Resistance (10 µA): 10 ohm. Resolution TE Current: 10 mA. Resolution TE Voltage: 0.1 Volts. Accuracy Temperature: ± 0.1 °C. Resistance (10 µA): ± (0.04% + 16 ohm). TE Current: ± (0.25% + 30 mA). TE Voltage: ± (0.005% + 100 mV). Display Type: LCD character display, 4 lines by 20 characters.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the NEWPORT 3150. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Amplified Spontaneous Emission Source (ASE)
ASE, a process where spontaneously emitted radiation (luminescence) is amplified. In lasers and particularly in high-gain erbium-doped amplifiers, amplified spontaneous emission is usually an unwanted effect. It tends to limit the gain achievable in a single stage of a fiber optic amplifier to the order of 40–50 dB.

Dynamic Range
In a transmission system, the ratio of the overload level to the noise level of the system, usually expressed in dB. Ratio of the highest to lowest detectable signal of a system, expressed in dB.

Optical Power
Optical Power is usually measured in "dBm", or decibels referenced to one miliwatt of power. while loss is a relative reading, optical power is an absolute measurement, referenced to standards. You measure absolute power to test transmitters or receivers and relative power to test loss.

Relative Wavelength Accuracy
When randomly changing the wavelength and measuring the differences between the actual and displayed wavelengths, the relative wavelength accuracy is ± half the span between the maximum and the minimum value of all differences.

Wavelength
Wavelength is a term for the color of light, usually expressed in nanometers (nm) or microns (m). In Fiber Optics the wavelenghts mostly used are in the infrared region where the light is invisible to the human eye.


Please contact us for your NEWPORT 3150 CALIBRATION and/or NEWPORT 3150 350 Watt Temperature Controller REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: