Keysight (Agilent) N4906A REPAIR and Keysight (Agilent) N4906A CALIBRATION

The Keysight (Agilent) N4906A is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) N4906A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) N4906A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Bit Error Rate Tester (BERT)?
Shop for Comparable Products on our
 used Bit Error Rate Tester (BERT) page or new Bit Error Rate Tester (BERT) page

 
   Keysight (Agilent) N4906A   Description / Specification:    
Keysight (Agilent) N4906A SerialBERT Bit Error Ratio Tester (BERT)

Agilent N4906A Serial BERT 3.6 Gb/s Bit Error Ratio Tester. Pattern generator parameters; Operating frequency: 50 MHz to 3.6 GHz with external clock (optional), 50 MHz to 3.0 GHz with internal clock source. Internal clock source frequency range: 50 MHz to 3.0 GHz. Internal clock source frequency accuracy: ±20 ppm. Error detector parameters; Operating frequency: 50 MHz to 3.6 GHz.. Test patterns: As specified for Pattern Generator. Auto-align: Includes synchronizing, data polarity, clock/data align, clock invert, 0/1 threshold center. Data in delay: Manual Data In Delay/Auto Clock-Data Align. Threshold setting: Manual set, Average DC level set, Auto 0/1 center. Synchronization: Manual, Automatic, Burst, Capture. Sync threshold adjustable from 10^ -1 to 10^ -9. Data entry: Touch-sensitive display, numeric keypad with up/down arrows, analogue feel position controls, or provided USB keyboard and mouse if desired. Display: Internal 8" (diagonal) backlit LCD touch-screen. Interfaces: GPIB (IEEE 488), LAN (10 Base T Ethernet) for printing and file transfer, Parallel/Centronics printer port, external VGA output.



 

Standard Calibration $1,025.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) N4906A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Communication Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Data Rate
Data Rate is the maximum number of bits of information which can be transmitted per second, as in a data transmission link. Typically expressed as megabits per second (Mbps).

Optical Signal-to-noise Ratio (OSNR)
Optical Signal-to-noise ratio is the ratio between the signal power and the noise power in a given bandwidth. Most commonly a reference bandwidth of 0.1 nm is used. This bandwidth is independent from the modulation format, the frequency and the receiver. For instance a OSNR of 20dB/0.1nm could be given, even the signal of 40 GBit DPSK would not fit in this bandwidth. OSNR is measured with a Optical Spectrum Analyzer. It is generally measured at the wavelength of interest.

SONET
Synchronous Optical NETwork (SONET) is a fiber-optic transmission system for high-speed digital traffic. Employed by telephone companies and common carriers, speeds range from 51 Mbps to 40 Gbps. SONET is an intelligent system that provides advanced network management and a standard optical interface. Specified in the Broadband ISDN (B-ISDN) standard, SONET backbones are widely used to aggregate T1 and T3 lines. The European counterpart to SONET is the Synchronous Digital Hierarchy, and the term "SONET/SDH" is widely used when referring to SONET


Please contact us for your Keysight (Agilent) N4906A REPAIR and/or Keysight (Agilent) N4906A SerialBERT Bit Error Ratio Tester (BERT) CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: