Keysight (Agilent) 53148A CALIBRATION and Keysight (Agilent) 53148A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 53148A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another General Meter?
Shop for Comparable Products on our
 used General Meter page

 
   Keysight (Agilent) 53148A   Description / Specification:    
Keysight (Agilent) 53148A 26.5 GHz Counter/Power Meter/DVM

The Agilent 53148A 26.5 GHz microwave counter/power meter/dvms has all the fundamental measurements required to install and maintain digital microwave radio links. Rugged field portability and a battery option complete the ensemble. This instrument is also at home in ATE applications with GPIB and RS-232 fully programmable I/O ports as standard features. Specifications. Frequency Range Input 1 (1 M-ohm): 10 Hz to 125 MHz. Frequency Range Input 2 (50 ohm): 0.05 - 26.5 GHz. Damage Level Input 1: 5 Vrms to 120 Vp. Damage Level Input 2: +27 dBm. Channel 1 Resolution: Selectable 1 Hz to 1 MHz. Channel 1 Low Pass Filter: 50 kHz, selectable. Channel 2 Resolution: Selectable 1 Hz to 1 MHz. Channel 2 Acquisition Time: 100 ms to 140 ms. Channel 2 Gate Time: 1/Resolution. Power Meter Specifications; Frequency Range: 10 MHz to 50 GHz, sensor-dependent. Power Range: –70 dBm to +20 dBm, sensor-dependent. Power Sensors: 8480 series. DVM Specifications; Function: DC volts. Range: ±50 Vdc. Display: Backlit LCD. Options. Opt 001 Oven Timebase. Opt 002 Battery/DC Input.



 

Standard Calibration $450.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 53148A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your Keysight (Agilent) 53148A CALIBRATION and/or Keysight (Agilent) 53148A 26.5 GHz Counter/Power Meter/DVM REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: