Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 81940A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 81940A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Tunable Laser Source (TLS)?
Shop for Comparable Products on our
 used Tunable Laser Source (TLS) page or new Tunable Laser Source (TLS) page

 
   Keysight (Agilent) 81940A   Description / Specification:   Spec Sheet 
Keysight (Agilent) 81940A 1520 to 1630 nm Compact Tunable Laser Source Module

The Agilent 81940A high power compact tunable laser enables optical device characterization at high power levels and measurement of nonlinear effects. It improves the testing of all types of optical amplifiers and other active components as well as broadband passive optical components. As single slot plug-in modules for Agilent's 8163A/B, 8164A/B and 8166A/B mainframes, they are a flexible and cost effective stimulus for single channel and DWDM test applications. Each module covers a total wavelength range of 110 nm in the C+L-band.
Specifications.

Wavelength range: 1520 nm to 1630 nm.
Wavelength (frequency) resolution: 1 pm, 125 MHz at 1550 nm
Mode-hop free tenability: Full wavelength range.
Maximum sweep speed: 50 nm/s.
Absolute wavelength accuracy: ± 20 pm, typical ± 5 pm.
Relative wavelength accuracy: ± 10 pm, typical ± 5 pm.
Wavelength repeatability: ± 2.5 pm, typical ± 1 pm.
Wavelength stability (typical, over 24 hours): ± 2.5 pm.
Linewidth (typical), coherence control off: 100 kHz.
Effective linewidth (typical), coherence control on: > 50 MHz (1570 nm to 1620 nm).
Maximum output power (continuous power during tuning):
  ≥ +14.5 dBm peak (typical),
  ≥ +13 dBm (1570 nm to 1620 nm),
  ≥ +10 dBm (1520 nm to 1630 nm).
Power linearity: ± 0.1 dB.
Power stability: ± 0.01 dB over 1 hour.
Power flatness versus wavelength: ± 0.2 dB, typical ± 0.1 dB (1570 nm to 1620 nm), ± 0.3 dB, typical ± 0.15 dB (full range).
Power repeatability (typical): ± 0.01 dB.
Side-mode suppression ratio (typical): ≥ 50 dB.

Options.
071, PMF, straight contact output connector.
072, PMF, angled contact output connector.



 

Standard Calibration $675.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 81940A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Coherence Time
Average time for the wave train to lose its phase realtionships

Fiber Bragg Grating (FBG)
A fiber Bragg grating (FBG) is a type of distributed Bragg reflector constructed in a short segment of optical fiber that reflects particular wavelengths of light and transmits all others. This is achieved by adding a periodic variation to the refractive index of the fiber core, which generates a wavelength specific dielectric mirror. A fiber Bragg grating can therefore be used as an inline optical filter to block certain wavelengths, or as a wavelength-specific reflector.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another. Adding information into pulses of light.

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, such as a fiber optic transmission system, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your Keysight (Agilent) 81940A REPAIR and/or Keysight (Agilent) 81940A 1520 to 1630 nm Compact Tunable Laser Source Module CALIBRATION

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: