FLUKE 185 CALIBRATION and FLUKE 185 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 185 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 185   Description / Specification:    
FLUKE 185 Handheld True RMS Digital Multimeter

The Fluke 185 is a Handheld True RMS Digital Multimeter featuring AC+DC true RMS measurements, 50.000 counts resolution and a 0.05% basic DC accuracy. The extra large dual display with analog bar graph and backlight ensure that readings are easy to read under all circumstances. The unit offers measurements of dB, temperature, a 4-20mA process loop percentage readout, min-max-average recording with timestamp, up to 30 readings, memories and a computer interface. The computer interface can also be used to perform closed case calibration and when the batteries run down you do not have to open the complete case and break the calibration seal to exchange them.
Specifications.

Voltage DC.
  Max: 1000 V.
  Max Resolution: 1 µV to 10 µV.
  Accuracy: ±(0.05%+1).

Voltage AC.
  Max: 1000 V.
  Max Resolution: 1 µV.
  Accuracy: ±(0.4%+2).

Current DC.
  Max: 10 A.
  Max Resolution: 0.01 µA.
  Accuracy: ±(0.2%+2).

Current AC.
  Max: 10 A.
  Max resolution: 0.01 µA ±(0.6%+2).

Resistance.
  Max: 50 MΩ to 500 MΩ.
  Max Resolution: 0.01 Ω.
  Accuracy: ±(0.1%+2).

Conductance.
  Max: 500 nS.
  Max Resolution: 0.01 nS.

Capacitance.
  Max: 50000 µF.
  Max Resolution: 0.001 nF.
  Accuracy: ±(1.0%+3).

Frequency.
  Max: 1 MHz.
  Max Resolution: 0.001 Hz.
  Accuracy: ±(0.002%+1).

Temperature.
  Max: -50°C/+980°C ; -200°C/+1350°C.
  Max Resolution: 0.1°C.

dBm and dBV.
  Max: -52/+60 dB ; -74/+60 dB
  Max Resolution: 0.01 dB.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your FLUKE 185 CALIBRATION and/or FLUKE 185 Handheld True RMS Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: