ADVANTEST Q7606B CALIBRATION and ADVANTEST Q7606B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ADVANTEST Q7606B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Lightwave Measurement System?
Shop for Comparable Products on our
 used Lightwave Measurement System page or new Lightwave Measurement System page

 
   ADVANTEST Q7606B   Description / Specification:    
ADVANTEST Q7606B Optical Chirpform Test Set

The Advantest Q7606B Optical Chirpform Test Set is a lightwave modulation test set, used together with a digital sampling oscilloscope, to separately measure and evaluate the chirp (frequency-modulated / FM) and intensity-modulated (IM) components of incident laser light. The Q7606B contains two sets of fiber-type Mach-Zehnder interferometers and their control circuits. The Q7606B can selectively output the sum of, or difference between the frequency-modulated / FM and IM components of the modulated incident light by switching the measurement mode. The sum (IM+FM) and difference (lM-FM) data are processed by the digital sampling oscilloscope and the personal computer to separate the chirp FM and IM components from each other, thus making it possible to evaluate the time-domain charactenstics. Specifications. Wavelength measurement range: 1510 to 1590 nm. Optical input power range: -20 to 10 dBm. Free Spectral Range: 150 GHz ±15 GHz. Demodulation band width (130 MHz as standard, 1 dB down):100 Hz to 50 GHz. Deviation of demodulation frequency: 65 GHz p-p or less. Resolution of demodulation frequency (Depends on the measurement resolution of an external sampling oscilloscope and input optical power.: 20 MHz p-p or less. Insertion Loss: 10 dB or less. Optical output power (Depends on the input optical power.): Input cal power (dBm) -10 dB or higher. Input light polarization compensation: Automatically controlled.



 

Standard Calibration $1,835.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ADVANTEST Q7606B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Amplified Spontaneous Emission Source (ASE)
ASE, a process where spontaneously emitted radiation (luminescence) is amplified. In lasers and particularly in high-gain erbium-doped amplifiers, amplified spontaneous emission is usually an unwanted effect. It tends to limit the gain achievable in a single stage of a fiber optic amplifier to the order of 40–50 dB.

Dynamic Range
In a transmission system, the ratio of the overload level to the noise level of the system, usually expressed in dB. Ratio of the highest to lowest detectable signal of a system, expressed in dB.

Optical Power
Optical Power is usually measured in "dBm", or decibels referenced to one miliwatt of power. while loss is a relative reading, optical power is an absolute measurement, referenced to standards. You measure absolute power to test transmitters or receivers and relative power to test loss.

Relative Wavelength Accuracy
When randomly changing the wavelength and measuring the differences between the actual and displayed wavelengths, the relative wavelength accuracy is ± half the span between the maximum and the minimum value of all differences.

Wavelength
Wavelength is a term for the color of light, usually expressed in nanometers (nm) or microns (m). In Fiber Optics the wavelenghts mostly used are in the infrared region where the light is invisible to the human eye.


Please contact us for your ADVANTEST Q7606B CALIBRATION and/or ADVANTEST Q7606B Optical Chirpform Test Set REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*