YOKOGAWA WT230-760502 CALIBRATION and YOKOGAWA WT230-760502 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA WT230-760502 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   YOKOGAWA WT230-760502   Description / Specification:    
YOKOGAWA WT230-760502 2-input Element Digital Power Meter

The Yokogawa 760502 WT230 2-input Element Digital Power Meter has five times the high-frequency range and approximately twice the basic accuracy as the previous generations plus a high-speed data acquisition rate and a compact design make this digital power meter highly desirable. Wiring Type: Single-phase 3-wire, Three-phase 3-wire (2 voltages, 2 currents). Specifications. Input type Voltage: Floating input, Resistance voltage divider. Input type Current: Floating input, Shunt input system. Rated values(ranges) Voltage: Crest factor 3, 15 / 30 / 60 / 150 / 300 / 600 V; Crest factor 6, 6, 7.5 / 15 / 30 / 75 / 150 / 300 V. Rated values(ranges) Current: Crest factor 3 Direct input: 0.5 / 1 / 2 / 5 / 10 / 20 A; Crest factor 6 Direct input: 0.25 / 0.5 / 1 / 2.5 / 5 / 10 A. Maximum continuous allowed input current: 0.5 - 20 A, Peak current of 100 A or rms value of 30 A (whichever is less). A/D converter simultaneous conversion of voltage and current inputs: Resolution 16 bits, Maximum conversion speed approximately 20 µs (approximately 51 kHz). Measurement functions. System: Digital sampling; sum of averages method. Frequency range: DC, and 0.5 Hz to 100 kHz. Crest factor: 3 or 6 (with rated input) 300 (with minimum effective input). Options. -C1, GP-IB communication interface. -C2, Serial (RS-232-C) communication interface. /EX1, External input 2.5/5/10 V. /EX2, External input 50/100/200 mV. /HRM, Harmonic measurement function. /DA12, 12-channel DA output. /CMP, Comparator and D/A, 4 channels each.



 

Standard Calibration $350.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA WT230-760502. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a component, link or network will operate.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Ringing
Ringing is an unwanted oscillation of a voltage or current.


Please contact us for your YOKOGAWA WT230-760502 CALIBRATION and/or YOKOGAWA WT230-760502 2-input Element Digital Power Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: