A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU 37217B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   ANRITSU 37217B   Description / Specification:    
ANRITSU 37217B 8.6 GHz Vector Network Analyzer

The Anritsu 37217B 8.6 GHz Vector Network Analyzer is a microprocessor controlled Analyzer. It is a single-instrument system that contains a built-in signal source, a test set, and an analyzer subsystem. The 37217B provides up to 1601 measurement data points, a built-in hard-disk drive for storing and recalling front panel setups and measurement and calibration data. It provides an on-screen display of total operational time and date of last system calibrations, and the number of power-off cycles since the last calibration.
Specifications

Frequency Range: 22.5 MHz to 8.6 GHz.
Max Signal Into Port 2: +3 dBm 0.0225 to 8.6 GHz.
Noise Floor: -95 dBm @ 0.0225 GHz, -98 dBm @ 2 GHz, -98 dBm @ 8.6 GHz.
Receiver Dynamic Range (defined as the ratio of the maximum signal level at Port 2 for 0.1 dB compression to the noise floor at Port 2): 98@ 0.0225 GHz, 101@ 2 GHz, 101 @ 8.6 GHz.
Port 1 Power: 0 dBm @ 0.0225 GHz to 8.6 GHz.
System Dynamic Range (defined as the ratio of the power incident on Port 2 in a through line connection to the noise floor at Port 2 (forward measurements only): 95 @ 0.0225 GHz, 98 @ 2 GHz, 98 @ 8.6 GHz.
High Level Noise (typical): <0.03 dB and <0.4° peak-to-peak variation in a 1 kHz IF bandwidth up to 8.6 GHz.
Measurement Time vs. Span for 101 Data Points (typical): 40 MHz to 8.6 GHz, 500 ms.
Number of Channels: Four independent measurement channels.
Parameters: S11, S21, S22, S12, or user-defined combinations of a1, a2, b1, and b2. All measurements are made without the need to manually reverse the test device.
Data Points: 1601 maximum.
GPIB Interfaces: 2.

Options
Opt 1, Rack Mounting.
Opt. 1A, Rack Mounting.
Opt 2, High Speed Time (Distance) Domain Measurement Capability.
Opt 4, External SCSI-2 Hard Disk Drive Compatibility. 
Opt 7A/N/NF/S/K, Universal Test Port Configuration, Replaces Universal / K Connector (standard) with: 7A - Universal / GPC-7, 7N - Universal / N, male, 7NF - Universal / N, female, 7S - Universal / 3.5 mm, male.
Opt 10A, High Stability Ovenized Time Base and 1 Hz Resolution.



 

Standard Calibration $690.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU 37217B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your ANRITSU 37217B CALIBRATION and/or ANRITSU 37217B 8.6 GHz Vector Network Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: