Keysight (Agilent) E5061A REPAIR and Keysight (Agilent) E5061A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) E5061A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E5061A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   Keysight (Agilent) E5061A   Description / Specification:    
Keysight (Agilent) E5061A 1.5 GHz ENA-L Network Analyzer

The Agilent E5061A 1.5 GHz ENA-L Network Analyzer provides basic vector network analysis in a wide range of industries and applications such as wireless communication, cable TV, automotive, education, and more. Designed to reduce tune and test times, these analyzers provide increased throughput to improve your measurement productivity. The ENA-L offers all of the critical performance and features needed in R&D, manufacturing, and service to test RF components such as: filters, amplifiers, antennas, cables, CATV taps, and distribution amplifiers. The E5061A ENA-L, with its > 120 dB dynamic range and 0.005 dB rms trace noise, provides the accuracy and speed required for many network measurement applications. The wide 30 kHz IF bandwidth (IFBW) and powerful digital processing provide unprecedented measurement speed. The S-parameter test set options offer full two-port calibration for optimum accuracy (Option 250 or 275). Test port output (source) Range: 300 kHz to 1.5 GHz. Resolution: 1 Hz. Source stability: ±5 ppm (5 °C to 40 °C). CW accuracy: ±5 ppm, 23 °C ±5 °C. Level accuracy (at 23 °C ±5 °C) 300 kHz to 1.5 GHz: ±0.8 dB (at 0 dBm, 50 MHz absolute), ±1.0 dB (at 0 dBm, relative to 50 MHz reference). Level linearity (at 23°C ±5°C) 300 kHz to 1.5 GHz: ±0.75 dB (at –5 to 10 dBm). Harmonics (2nd or 3rd) 10 MHz to 2 GHz: < –25 dBc (at 5 dBm). Maximum test port input level 300 kHz to 3 GHz: +10 dBm. IF bandwidth settings Range: 10 Hz to 30 kHz, Nominal settings are: 10, 30, 100, 300, 1 k, 3 k, 10 k, 30 k. Display: 10.4 in TFT color LCD. GPIB 24-pin D-Sub (type D-24), female; compatible with IEEE-488. Options. 150, TR test set 50 ohm system impedance. 175, TR test set 75 ohm system impedance. 250, S-parameter test set 50 ohm system impedance with extended power range. 275, S-parameter test set 75 ohm system impedance with extended power range. 1E1, Extended power range (-45 to 10 dBm). 100, Add fault location and SRL analysis. 016, Touch screen color LCD.



 

Standard Calibration $785.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E5061A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

White Noise
White noise is noise whose power spectral density (watts/hertz) is constant for the frequency range of interest.


Please contact us for your Keysight (Agilent) E5061A REPAIR and/or Keysight (Agilent) E5061A 1.5 GHz ENA-L Network Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: