Keysight (Agilent) E5070B CALIBRATION and Keysight (Agilent) E5070B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E5070B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   Keysight (Agilent) E5070B   Description / Specification:   Spec Sheet 
Keysight (Agilent) E5070B 3 GHz ENA RF Network Analyzer

The Agilent E5070B 300 kHz to 3 GHz ENA RF Network Analyzer dramatically improves measurement accuracy and responds to current and future test needs. Because it performs up to 125 dB2 wide dynamic range at 10 Hz IFBW, the sweep speed can be faster at the required dynamic range. The trace noise is lowered to 0.001 dB rms at 3 kHz IFBW. It delivers accurate pass band ripple measurement of a filter. The Agilent E5070B offers integrated 2, 3, or 4 test ports, and enable various component measurements from 2-port filters to multiport devices like duplexers and couplers. The ENA offers built-in balanced measurements, matching circuit simulation, and port characteristic impedance conversion. In addition, the ENA provides frequency-offset and harmonics measurement capabilities. Specifications. Test Frequency range: 300 kHz to 3 GHz. Max port output power: -50 to 10 dBm. Test set: S-parameter test set. Number of test ports: 2, 3 or 4. IFBW: 10 Hz to 100 kHz (1, 1.5, 2, 3, 4, 5, 7 step). Number of points: 2 to 20,001. System dynamic range: 122 dB at 10 Hz BW (1.5 GHz to 3 GHz). Trace noise (magnitude): 0.001 dBrms at 3 kHz BW (3 MHz to 3 GHz). Display Size: 10.4 in TFT color LCD. Options. -008, Frequency-offset mode. -010, Time domain analysis capability. -790, Measurement wizard assistant software. -214, Two-port S-parameter test set. -314, Three-port S-parameter test set. -414, Four-port S-parameter test set. -016, Touch screen color LCD. -1E5, High stability frequency reference.



 

Standard Calibration $785.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E5070B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

White Noise
White noise is noise whose power spectral density (watts/hertz) is constant for the frequency range of interest.


Please contact us for your Keysight (Agilent) E5070B CALIBRATION and/or Keysight (Agilent) E5070B 3 GHz ENA RF Network Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: