ANRITSU MS4624C CALIBRATION and ANRITSU MS4624C REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU MS4624C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   ANRITSU MS4624C   Description / Specification:   Spec Sheet 
ANRITSU MS4624C 9 GHz Vector Network Measurement System/ Direct Receiver Acc

The Anritsu MS4624C 9 GHz, 2-Port Vector Network Measurement System / Direct Receiver Access with direct access to the receivers (i.e. without an integrated test set). This vector network analyzer offers the ultimate flexibility for power amplifiers, frequency translating, and multiple output device requirements. Specifications. Frequency Range: 10 MHz to 9 GHz. Source Power Range (No Options): +7 to –85 dBm. Level Accuracy: ±1.5 dB. Sweep Range: 20 dB Minimum. Harmonics: –25 dBc. Stability: <5 ppm / year. Receiver Average Noise, 10 Hz: –115 dBm (<3 GHz), –115 dBm (3 to 6 GHz), –105 dBm (6 to 9 GHz). Receiver 0.1 dB Compression: +7 dBm. Receiver Maximum Input: +27 dBm. Receiver Damage Level: +30 dBm. System Dynamic Range (Terminated): 125 dB (10 to 3000 MHz), 120 dB (3000 to 6000 MHz), 110 dB (6000 to 9000 MHz). High Level Noise: <0.008 dB rms (10 to 3000 MHz), <0.018 dB rms (3000 to 6000 MHz), <0.018 dB rms (6000 to 9000 MHz). IF Bandwidth Range: 10 Hz, 30 Hz, 100 Hz, 300 Hz, 1 kHz, 3 kHz, 10 kHz, and 30 kHz. Data Points: 1, 3, 15, 51, 101, 201, 401, 801, and 1601; Arbitrarily use Discrete Fill for 2 to 1601 points. Impedance: 50 Ohms. Frequency Resolution: 1 Hz. Power Output Range Source 1 (2-Ports No Options): +10 to –85 dBm (10 MHz to 3 GHz), +7 to –85 dBm (10 MHz to 9 GHz). Power Control Range: >20 dB. The minimum absolute level for power sweep is -15 dBm while the maximum power output for a unit is typically +10 dBm, depending upon configuration. Power Level Accuracy: ±1 dB to 6 GHz, ±1.5 dB to 9 GHz (no flat power calibration applied; full-band frequency sweep at -15 dBm, 0 dBm, and maximum rated power). Sweep Type: Linear, CW, Marker, or N-Discrete point sweep. Liquid Crystal Display: A Color 8.4" Thin Film Transistor (TFT) LCD display. Options. 1: Rack Mount Kit. 1A: Rack Mount Kit for use with System Console. 2: Time (Distance) Domain Measurement Capability. 3D: Second Internal Source, Third Test Port. 4D: Noise Figure, 50 MHz to 3 GHz. 4E: Noise Figure, 50 MHz to 6 GHz. 6: Third Test Port Without Second Internal Source. 8: Harmonic Measurements. 13: Intermodulation Distortion (IMD). 15: Internal 500 MB Hard Drive.



 

Standard Calibration $720.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU MS4624C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

White Noise
White noise is noise whose power spectral density (watts/hertz) is constant for the frequency range of interest.


Please contact us for your ANRITSU MS4624C CALIBRATION and/or ANRITSU MS4624C 9 GHz Vector Network Measurement System/ Direct Receiver Acc REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: