Custom-Cal has a high success rate in the repair of the ANRITSU S331D. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU S331D Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Cellular Test Set? Shop for Comparable Products on our   new Cellular Test Set page

 
   ANRITSU S331D   Description / Specification:    
ANRITSU S331D 4 GHz Site Master Antenna and Cable Analyzer

The Anritsu S331D Site Master is a precision hand-held return loss/SWR and fault location measurement instrument. OSL calibration can be applied to all 1-port measurements (RL/VSWR/cable Loss/DTF) enabling accurate vector corrected measurements. Site Masters' SPA has dedicated routines for one-button measurements of field strength, channel power, occupied bandwidth, adjacent channel power ratio (ACPR), Carrier-to-Interference, and interference analysis. Light weight, rugged design, and wide temperature range make them ideal for field applications. The S331D Site Master’s proprietary design provides superior immunity to on-channel RF interference, which is important for live site testing. Features. Accurate return loss/SWR and fault location measurements. Accurately tests RF transmission lines and antennas. Superior immunity to on-channel interference for testing at co-located antenna sites.
Specifications

Frequency range: 25 MHz to 4.0 GHz.
Frequency Resolution: 100 kHz.
Frequency Accuracy (CW Mode): ± 75 parts per million.
Display data points Selectable: 130, 259, 517.
Immunity to interfering RF signals: -5 dBm (On-frequency), +17 dBm (On-channel).
Return Loss Range: 0.0 to 60.00 dB, Resolution: 0.01 dB.
VSWR: Range 1 to 65.53, Resolution: 0.01 dB.
Cable loss: Range 0 to 30, Resolution: 0.01 dB.
Distance-To-Fault (DTF) Vertical Range: Return loss, 0 to 60 dB; SWR, 1 to 65.53.
DTF Horizontal range (meter): 0 to (# of data points -1) x horizontal resolution, where data points = 130, 259 or 517.
Maximum Input (Damage Level) +20 dBm.

Options
3: Color daylight viewable TFT display.
5: Power Monitor to measure power - external detector needed.
29: Power Meter from 3 MHz to 3 GHz.
31: Built-in GPS receiver provides latitude, longitude, altitude information with trace data.
50: T1/E1 Analyzer.



 

Standard Calibration $510.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU S331D. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Communication Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bit Error Ratio (BER)
Bit Error Ratio (BER) is the ratio of errors caused by the number of bits in a data stream that have been altered due to noise, interference, distoriton or bit synchronization errors.

Multiplexing
Multiplexing (also known as muxing) is a method by which multiple analog message signals or digital data streams are combined into one signal over a shared medium. Multiplexing divides the capacity of the low-level communication channel into several higher-level logical channels, one for each message signal or data stream to be transferred.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your ANRITSU S331D REPAIR and/or ANRITSU S331D 4 GHz Site Master Antenna and Cable Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: