A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU ML2496A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Power Meter?
Shop for Comparable Products on our
 used RF Power Meter page

 
   ANRITSU ML2496A   Description / Specification:    
ANRITSU ML2496A 2 Channel Pulse RF Power Meter

The Anritsu ML2496A 2 Channel Pulse RF Power Meter is suited for Wideband power measurements on signals such as W-CDMA, WLAN, and WiMAX. Several different families of power sensors are available with frequency coverage to 50 GHz and dynamic range up to 90 dB. Most of the power sensors can work in either pulsed/modulated or CW mode. PowerMax is a free graphical user-interface software that provides an enhanced visualization of instrument display and simplified remote control of the instrument. Compatible with Anritsu MA and MP series sensors. Specifications. Frequency range: 100 kHz to 65 GHz (sensor dependent). Dynamic range: –70 to +20 dBm (dependent on sensor, external coupler or attenuator). Sampling rate CW Mode: 75 kS/s. Sampling rate Pulse/Modulated Mode: 31.25 kS/s to 62.5 MS/s Continuous Sampling (Trigger capture time 3.2 µs to 7s, 200 data points). System rise-time (10% to 90% at +10 dBm): Typical 8 ns, Maximum 12 ns (with MA2411B sensor). Rise-time measurement dynamic range: 10% to 90% Rise-time measurement of –20 dBm to +20 dBm Peak power (with MA2491A). Source sweep: Single channel power sweep or frequency sweep. Display resolution in Readout mode: 0.1 to 0.001 dB. Measurement hold: Hold, Max, Min. Measurements: Average, Min, Max, Peak, Crest, PAE (Power Added Efficiency). Voltage measurement range: 0.00 to 20.00V nominal. Display range: –199.99 to +199.99 dB. Display: Color LCD.



 

Standard Calibration $350.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU ML2496A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.


Please contact us for your ANRITSU ML2496A CALIBRATION and/or ANRITSU ML2496A 2 Channel Pulse RF Power Meter REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: