Keysight (Agilent) DSO3152A CALIBRATION and Keysight (Agilent) DSO3152A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) DSO3152A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) DSO3152A   Description / Specification:    
Keysight (Agilent) DSO3152A 2 Ch 150 MHz Digital Storage Oscilloscope

The Agilent DSO3152A 150 MHz oscilloscope comes standard with advanced features including sophisticated triggering, automatic measurements, digital filtering, sequence mode acquisition, math functions (including FFTs), stored setups and waveforms, mask testing. It has a color display to allow you to quickly identify your signals, and the large size – 15-cm (5.7-in) with 320 x 240 resolution. The Agilent DSO3102A oscilloscope comes standard with an N2865A USB host module for saving setups, waveforms and displays to a memory stick. This port is also compatible with many USB printers. Digital filtering selections include low pass, high pass, band pass, and band reject filters. Limits are selectable between 1-kHz and the bandwidth of your oscilloscope. Specifications. Bandwidth: 150 MHz. Real time sample rate: 1 GSa/s (2 channels interleaved), 500 MSa/s (Each channel). Channels: 2. Memory: 4 kpts per channel; 1.200 pts in roll mode. Vertical resolution: 8 bits. Vertical sensitivity: 2 mV/div to 5 V/div. DC gain accuracy: ± 3% for 10 mV/div to 5 V/div; ± 4% for 2 mV/div to 5 mV/div. Vertical zoom: Vertical expand. Maximum input voltage: 300 Vrms CAT II; derated at 20 dB/decade above 100 kHz to 13 V p-p AC at 3 MHz and above. Time base range: 2 ns/div to 50 s/div. BW limit: ~ 20 MHz. Input coupling: DC, AC, Ground. Input impedance 1 Mohm ~ 13 pF. Time base accuracy: 100 ppm.



 

Standard Calibration $300.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) DSO3152A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your Keysight (Agilent) DSO3152A CALIBRATION and/or Keysight (Agilent) DSO3152A 2 Ch 150 MHz Digital Storage Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: