Keysight (Agilent) DSO5054A CALIBRATION and Keysight (Agilent) DSO5054A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) DSO5054A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) DSO5054A   Description / Specification:    
Keysight (Agilent) DSO5054A 4 Ch 500 MHz InfiniiVision Oscilloscope

The Agilent DSO5054A 500 MHz InfiniiVision oscilloscope offers responsive deep memory, fast update rates with minimal “dead time,” analog-like display systems, and integrated serial analysis. If you are characterizing signal jitter, a fast update rate gives you accurate results sooner. And when the fast update rate is combined with the 5000 Series’ XGA high-definition display (1024 x 768, 256 intensity levels), subtle differences in these acquisitions become obvious. The Agilent DSO5054A offers up to 12 bits of vertical resolution in real-time, single-shot mode. Analysis functions include subtract, multiply, integrate, and differentiate, as well as Fast Fourier Transforms (FFT). Specifications. Bandwidth: 500 MHz. Maximum sample rate: 4 GSa/s. Channels: 2 Ch 1, 2, 3, and 4 simultaneous acquisition. Memory: Up to 8 Mpts. Vertical resolution: 8 bits, up to 12 in high-resolution or averaging modes. Peak detection: 250 ps peak detect. Averaging: Selectable from 2, 4, 8, 16, 32, 64 ... to 65536. Calculated rise time (= 0.35/bandwidth): 700 ps. Range: 2 mV/div to 5 V/div (1 Mohm or 50 ohm). Input impedance: 1 Mohm ± 1% || 12 pF or 50 ohm ± 1.0%, selectable. Horizontal Range: 1 nsec/div to 50 sec/div. Resolution: 2.5 psec. Trigger Sources: Ch 1, 2, 3, 4, line, ext. Display: 6.3-inch (161 mm) diagonal color TFT LCD. Option 080, 8 Mpts memory upgrade (from base 1 Mpts).



 

Standard Calibration $460.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) DSO5054A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your Keysight (Agilent) DSO5054A CALIBRATION and/or Keysight (Agilent) DSO5054A 4 Ch 500 MHz InfiniiVision Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: