AMPROBE 15XP-A CALIBRATION and AMPROBE 15XP-A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AMPROBE 15XP-A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   AMPROBE 15XP-A   Description / Specification:   Spec Sheet 
AMPROBE 15XP-A Digital Multimeter with Logic Test

The Amprobe 15XP-A is the right choice for electronics engineers, technicians and field service with TTL logic test for digital circuits. Data Hold freezes display to “hold” measurement reading. Specifications. DC Voltage ranges: 200 mV, 2 V, 20 V, 200 V, 1000 V. DC Voltage accuracy: ± (0.5 % rdg + 1 dgt). DC Voltage resolution: 100 µV. AC Voltage (45 Hz to 500 Hz) ranges: 200 mV (45 Hz to 100 Hz), 2 V, 20 V, 200 V, 750 V. AC Voltage (45 Hz to 500 Hz) accuracy: 200 mV (45 Hz to 100 Hz), 2 V, 20 V, 200 V, 750 V ± (1.5 % rdg + 5 dgts). AC Voltage (45 Hz to 500 Hz) resolution: 100 µV. DC Current ranges: 200 µA, 2000 µA, 20 mA, 200 mA, 2 A. DC Current accuracy: 200 µA to 200 mA ranges ± (1.0 % rdg + 2 dgt), 2 A range: ± (2.0 % rdg + 3 dgts). DC Current resolution: 0.1 µA. AC Current (45 Hz to 500 Hz) ranges: 200 µA, 2000 µA, 20 mA, 200 mA, 2 A.. AC Current (45 Hz to 500 Hz) accuracy: 200 µA to 200 mA ranges ± (1.5 % rdg + 2 dgts), 2A range: ± (2.0 % rdg + 3 dgts). AC Current resolution: 0.1 µA. Resistance Ranges: 200 ohm, 2 kohm, 20 kohm, 200 kohm, 2 Mohm, 2000 Mohm. Resistance Accuracy: 200 ohm to 2 Mohm ranges ± (1.5 % rdg + 5 dgts), 2000 Mohm range ± {5.0 % (rdg -10 dgts) +20 dgt}. Resistance Resolution: 100 mohm. Continuity Audible Indication: < 25 ohm. Overload Protection: 1000 V DC or 750 V AC RMS. Diode Test Current: 1.2 mA (approximate). Logic Test: TTL. Non-Contact Voltage Indicator: Sense voltage 70 V to 600 V ac (50 Hz to 60 Hz) beeper chirps and big bright red LED comes on, works on all ranges. Display: 3-1/2 digit liquid crystal display (LCD) with a maximum reading of 1999.



 

Standard Calibration $90.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AMPROBE 15XP-A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your AMPROBE 15XP-A CALIBRATION and/or AMPROBE 15XP-A Digital Multimeter with Logic Test REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: