Keysight (Agilent) E5515C REPAIR and Keysight (Agilent) E5515C CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) E5515C. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E5515C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Cellular Test Set? Shop for Comparable Products on our   new Cellular Test Set page

 
   Keysight (Agilent) E5515C   Description / Specification:    
Keysight (Agilent) E5515C 8960 Series 10 Wireless Communications Test Set

The Agilent E5515C 8960 Series 10 Wireless Communications Test Set is the world’s most trusted solution for wireless device manufacturing and RF design and verification. The proven 8960 test applications, developed for high-volume, automated wireless device manufacturing test, offer speed, accuracy, repeatability, and ease of programming, all on the format-flexible E5515C architecture. For the mobile manufacturer, this translates into lower test costs and higher production output to help meet customer demand for phones now and into the future. The 8960’s flexible, accurate and fast RF measurements, coupled with a fully flexible yet easy-to-use network emulator help you design, integrate and verify your RF devices faster. Add the full-featured wireless test manager (WTM) software for automated RF parametric testing of 3GPP and 3GPP2 minimum performance standards to find issues sooner and resolve them faster! Ensure your device moves quickly through the RF conformance process with the GS-8800 RF design verification and conformance test systems; scalable high-performance test systems built around the 8960’s measurement speed, accuracy and repeatability. Further, the GS-8800 software includes pre-defined tests that conform to individual technology standards and can be easily configured or modified when used in the design verification environment. Features. Supports GSM / GPRS / EGPRS / E-EDGE, W-CDMA / HSPA / HSPA+, cdma2000® / 1xEV-DO / eHRPD, TD-SCDMA/TD-HSDPA/TD-HSUPA, IS-95, TIA/EIA-136 and AMPS wireless device testing. Software upgradeable for quick access to new functionality. Integrate with WTM software for quick automation of RF and parametric tests. Remotely controllable through GPIB interface. Specifications. 292 to 2700 MHz frequency range includes all commercial 3GPP and 3GPP2 frequency bands. -110 to -13 dBm output level range with modulation. VSWR <1.2:1 400 to 2000 MHz. < +/-1.0 dB channel power measurement accuracy. Options. Opt 002, 2nd RF source. Opt 003, Flexible CDMA base station emulator. Opt 004, Digital bus. Opt AX3, Front handle kit. Opt AX4, Rack flange kit. Opt AX5, Flange and handle kit. Opt R45, Hardware revision 4.5. Opt R48, Hardware revision 4.8. Opt R50, Hardware revision 5.0. Opt R51, Hardware revision 5.1. Opt R55, Hardware revision 5.5. Opt R58, Hardware revision 5.8. Opt R70, Hardware Revision 7.0.



 

Standard Calibration $540.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E5515C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Communication Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Extinction Ratio
Extinction ratio is the ratio of two optical power levels, of a digital signal generated by an optical source, where P1 is the optical power level generated when the light source is "on," and P0 is the power level generated when the light source is "off." The extinction ratio may be expressed as a fraction, in dB, or as a percentage. Extinction ratio = P1/P0

Receiver
A receiver is a detector and electronic circuitry to change optical signals into electrical signals.

Telecom Bands
Optical fiber communications typically operate in a wavelength region corresponding to one of the following Bands. O Band (original): 1260–1360 nm. E Band (extended): 1360–1460 nm. S Band (short wavelengths): 1460–1530 nm. C Band (conventional): 1530–1565 nm. L Band (long wavelengths): 1565–1625 nm. U Band (ultralong wavelengths): 1625–1675 nm


Please contact us for your Keysight (Agilent) E5515C REPAIR and/or Keysight (Agilent) E5515C 8960 Series 10 Wireless Communications Test Set CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: