ILX LIGHTWAVE LDT-5948 CALIBRATION and ILX LIGHTWAVE LDT-5948 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ILX LIGHTWAVE LDT-5948 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another TEC Temperature Controller?
Shop for Comparable Products on our
 used TEC Temperature Controller page

 
   ILX LIGHTWAVE LDT-5948   Description / Specification:    
ILX LIGHTWAVE LDT-5948 5 A / 12 V Precision Temperature Controller

The ILX LDT-5948 60W Precision Temperature Controller is a bi-directional current source with precision measurement circuits to monitor and control the temperature of the device under test. Temperature Control Output Range: -50 degC to +250.000 degC, IC Sensor: -50 degC to +150.000 degC, RTD: -50 degC to +199.999 degC, Setpoint Accuracy T Mode: +/-0.005 degC, Ite Mode: +/-0.03A, Vte Mode: +/-0.05V (typical), Setpoint Resolution T Mode: 0.001 degC, Ite Mode: 0.001A, Vte Mode: 0.001V, Temperature Stability (24 hours): +/-0.005 degC. Output Type: bidirectional current source, +/-12 VDC, -5.000 to 5.000 A, 60 W, 15 mA rms current noise and ripple (typical). Current Limit Range -5 A to 5 A @ +/-0.050 A.



 

Standard Calibration $350.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ILX LIGHTWAVE LDT-5948. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Amplified Spontaneous Emission Source (ASE)
ASE, a process where spontaneously emitted radiation (luminescence) is amplified. In lasers and particularly in high-gain erbium-doped amplifiers, amplified spontaneous emission is usually an unwanted effect. It tends to limit the gain achievable in a single stage of a fiber optic amplifier to the order of 40–50 dB.

Dynamic Range
In a transmission system, the ratio of the overload level to the noise level of the system, usually expressed in dB. Ratio of the highest to lowest detectable signal of a system, expressed in dB.

Optical Power
Optical Power is usually measured in "dBm", or decibels referenced to one miliwatt of power. while loss is a relative reading, optical power is an absolute measurement, referenced to standards. You measure absolute power to test transmitters or receivers and relative power to test loss.

Relative Wavelength Accuracy
When randomly changing the wavelength and measuring the differences between the actual and displayed wavelengths, the relative wavelength accuracy is ± half the span between the maximum and the minimum value of all differences.

Wavelength
Wavelength is a term for the color of light, usually expressed in nanometers (nm) or microns (m). In Fiber Optics the wavelenghts mostly used are in the infrared region where the light is invisible to the human eye.


Please contact us for your ILX LIGHTWAVE LDT-5948 CALIBRATION and/or ILX LIGHTWAVE LDT-5948 5 A / 12 V Precision Temperature Controller REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: